Related Experiment Video
Updated: Jun 12, 2026

In Situ Lithiated Reference Electrode: Four Electrode Design for In-operando Impedance Spectroscopy
Published on: September 12, 2018
New selenite ion-selective electrodes based on 5,10,15,20-tetrakis-(4-methoxyphenyl)-21H,23H-porphyrin-Co(II)
H Ibrahim1, Y M Issa, Ola R Shehab
1Chemistry Department, Faculty of Science, Cairo University, Cairo, Egypt.
Abstract:
New polymeric membrane (PME), modified carbon paste (MCPE), and coated wire (CWE) selenite ion-selective electrodes based on 5,10,15,20-tetrakis-(4-methoxyphenyl)-21H,23H-porphyrin-Co(II) (CoTMeOPP) are reported. The best composition was the electrode containing 2% CoTMeOPP as the active material and 49% TCP as plasticizer. The electrodes reveal a Nernstian behavior over a concentration range of 5.5x10(-5) to 1.1x10(-2) M for PME, 5.2x10(-5) to 1.2x10(-2) M for MCPE and 1.2x10(-4) to 4.4x10(-3) M for CWE. The potentiometric response is pH dependent, since selenous acid is a diprotic acid. The slope of the selenite PVC electrode was -57.0 mV for the monovalent anion at pH 6.47, and -26.0 mV for the divalent anion at pH 11.00. The detection limits were 3.4x10(-5) and 4.7x10(-5) M at pH values 6.47 and 11.00, respectively. The electrodes manifest advantages of low resistance, very short response time (15 s), and most importantly good selectivities relative to a wide variety of other anions. In fact, the proposed selenite ion-selective electrodes show a great improvement compared to previously reported electrodes for selenite ion. The electrode was used for the determination of selenite in selenite/selenate mixture, in sodium selenite raw material powder, and in VitaFit Selenium ACE antioxidant tablets with recovery ranges of 90.0-103.3%.
More Related Videos
07:54Analysis of AtHIRD11 Intrinsic Disorder and Binding Towards Metal Ions by Capillary Gel Electrophoresis and Affinity Capillary Electrophoresis
Published on: August 22, 2018
12:52Iridium(III) Luminescent Probe for Detection of the Malarial Protein Biomarker Histidine Rich Protein-II
Published on: July 7, 2015
Related Concept Videos
Potentiometry: Membrane Electrodes
Ion-Exchange Chromatography
Potentiometry: Types of Electrodes
The Standard Hydrogen Electrode (SHE) is a widely used reference electrode that maintains zero potential across all temperatures. However, its need for a continuous hydrogen gas supply renders it impractical for everyday use.
An alternative to SHE is the Saturated Calomel Electrode (SCE). This electrode features an...