Resolution of resultant displacement into components in double exposure speckle photography
Applied Optics
|June 22, 2010
Abstract:
An equation to resolve the resultant displacement, recorded using double exposure laser speckle photography, at the surface of a cylinder suffering radial expansion, axial twist, and transverse displacement, into these three components is presented.
Related Concept Videos
Super-resolution Fluorescence Microscopy
Super-resolution fluorescence microscopy (SRFM) provides a better resolution than conventional fluorescence microscopy by reducing the point spread function (PSF). PSF is the light intensity distribution from a point that causes it to appear blurred. Due to PSF, each fluorescing point appears bigger than its actual size, and it is the PSF interference of nearby fluorophores that causes the blurred image. Various approaches to achieving higher resolution through SRFM have recently been developed.
Chromatographic Resolution
In chromatography, a solute moves through a chromatographic column and tends to spread, forming a Gaussian-shaped band. The longer the solute spends in the column, the broader the band becomes. The broadening can lead to overlaps within the column, affecting separation effectiveness.
The effectiveness of separation can be evaluated by determining the level of separation between two neighboring peaks in a chromatogram, which represents the individual components of a sample.
In chromatography,...
The effectiveness of separation can be evaluated by determining the level of separation between two neighboring peaks in a chromatogram, which represents the individual components of a sample.
In chromatography,...
Phase Contrast and Differential Interference Contrast Microscopy
Phase-Contrast Microscopes
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...