Related Experiment Video
Updated: Jun 12, 2026

Povidone Iodine Rectal Preparation at Time of Prostate Needle Biopsy is a Simple and Reproducible Means to Reduce Risk of Procedural Infection
Published on: September 21, 2015
An independent in vitro comparison of povidone iodine and SteriLid
Drew R Chronister1, Regis P Kowalski, Francis S Mah
1The Charles T. Campbell Ophthalmic Microbiology Laboratory, University of Pittsburgh Medical Center, Pittsburgh, Pennsylvania, USA.
Aim:
Povidone iodine (PI) and SteriLid (SL) are biocides used to decrease bacterial load on the eyelid margin. We compared the antibacterial activity of PI and SL to determine the better antiseptic.
Methods:
Time-kill studies of PI and SL against a battery of bacteria that included Staphylococcus epidermidis, methicillin-susceptible Staphylococcus aureus, methicillin-resistant Staphylococcus aureus, Streptococcus pneumoniae, Bacillus cereus, Pseudomonas aeruginosa, Escherichia coli, Serratia marcescens, and Branhamella catarrhalis were conducted at time points 1, 2, 10, and 30 min. The comparative outcome measures were based on 90% and 99.9% decreases in bacterial colony counts.
Results:
PI was more effective at a 90% kill than SL at time points, 1 min (8/9 vs. 7/9), 2 min (9/9 vs. 6/9), 10 min (9/9 vs. 8/9), and 30 min (9/9 vs. 8/9). PI was more effective at a 99.9% kill than SL at time points, 1 min (5/9 vs. 3/9), 2 min (7/9 vs. 4/9), 10 min (9/9 vs. 4/9), and 30 min (9/9 vs. 6/9).
Conclusions:
Our study supports PI as an effective antiseptic for decreasing the bacterial load that can exist on the eyelid margin. SL appears to be a less effective alternative.
Related Concept Videos
Hand hygiene
Hand washing...
Methods of Sterilization I: Physical Methods
Steam sterilization uses non-toxic, low-cost moist heat in the form of saturated steam under pressure, which is fast, microbicidal, and sporicidal, and quickly warms and penetrates fabrics. Autoclaves, or steam sterilizers, expose each item to direct steam contact for a predetermined time at the necessary...
Methods of Sterilization II: Chemical Methods
Using chemical sterilization rather than heat to clean out equipment is recommended. It eradicates and removes all bacteria,...
Pharmaceutical Alternatives: Stability-Related Therapeutic Nonequivalence
Equivalence: In Vitro and In Vivo Bioequivalence
Cleaning, Sterilization, and Disinfection
Cleaning
The cleaning process usually involves using water with detergents or enzymatic cleaner and removing foreign material from objects and surfaces, including organic material such as body fluids or inorganic material like soil. Cleaning is performed before high-level disinfection and sterilization because foreign materials on the cover of the devices interfere with process...