Related Experiment Video
Updated: Jun 12, 2026

Assessing Cerebral Autoregulation via Oscillatory Lower Body Negative Pressure and Projection Pursuit Regression
Published on: December 10, 2014
Low-frequency oscillations in R-R interval and blood pressure across the continuum of cardiovascular risk
Antti M Kiviniemi1, Suvi Tiinanen, Arto J Hautala
1School of Kinesiology, Faculty of Health Sciences, University of Western Ontario, London, Canada. antti.kiviniemi@verve.fi
Abstract:
The purpose of this study was to assess the power and the frequency of low-frequency (LF; 0.04-<0.15 Hz) oscillations in systolic blood pressure (SBP) and R-R interval (RRi) across the continuum of risk of cardiovascular disease, including age. A potential confound in such determinations is low spontaneous breathing frequency in some individuals. We measured beat-to-beat SBP, RRi and respiration in healthy YOUNG (33±3 years) and OLDER subjects (62±5 years) and older patients with hypertension (HT, 61±5 years), coronary artery disease without (CAD, 62±5 years) and with type 2 diabetes (CAD+DM, 62±4 years, n=28 for all groups) during spontaneous breathing at supine rest. Power (Power(LF)) and median frequency (Med(LF)) of LF oscillations were calculated by power spectral analysis after removing respiratory effects by least-mean-square adaptive filtering. OLDER had higher Power(LF-SBP) (5.5±3.0 vs. 3.4±2.5 mmHg(2), p=0.002) and lower Power(LF-RRi) than YOUNG (339±460 vs. 575±422 ms(2), p=0.001) whereas neither variable differed between OLDER and patient groups. Med(LF-SBP) (0.072±0.009 vs. 0.080±0.011 Hz, p=0.005) and Med(LF-RRi) (0.072±0.010 vs. 0.079±0.013 Hz, p=0.027) were lower in OLDER compared with YOUNG. Compared with OLDER, Med(LF-RRi) was lower in CAD (0.065±0.006 Hz, p=0.015) and CAD +DM (0.066±0.008 Hz, p=0.012); whereas CAD+DM had also lower Med(LF-SBP) (0.065±0.006 Hz, p=0.012). No differences were observed between OLDER and HT and between CAD and CAD+DM in these variables. We concluded that age is major determinant of the power of LF oscillations in SBP and RRi at rest, whereas the median frequency of these oscillations is altered also by coronary artery disease.
Related Concept Videos
Measurement of Blood Pressure
Factors affecting Blood pressure
Physiological Factors:
Alterations in Blood Pressure
Hypertension (High blood pressure)
Hypertension occurs when blood pressure readings consistently exceed the normal range. It is diagnosed when systolic blood pressure (the top number, indicating pressure while the heart beats)...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.

