Related Experiment Videos
Association between routine and standardized blood pressure measurements and left ventricular hypertrophy among
Jaspreet Khangura1, Bruce F Culleton, Braden J Manns
1Department of Medicine, University of British Columbia, Vancouver, Canada.
Insights
Standardized blood pressure (BP) measurements strongly predict left ventricular (LV) hypertrophy in hemodialysis patients. Pre-dialysis BP is a weak predictor, suggesting guidelines may need updating.
Area of Science:
- Nephrology
- Cardiology
- Hypertension Management
Background:
- Left ventricular (LV) hypertrophy is prevalent in hemodialysis patients.
- The relationship between blood pressure (BP) and LV hypertrophy is known, but the optimal BP measurement method remains unclear.
Purpose of the Study:
- To assess agreement between various BP measurement methods.
- To identify the strongest BP measurement correlate of LV hypertrophy in hemodialysis patients.
Main Methods:
- Post-hoc analysis of a randomized controlled trial data.
- Evaluated seven BP measurement methods including standardized, pre-dialysis, post-dialysis, intra-dialytic, and cumulative readings.
- Assessed agreement using Lin's CCC and Bland Altman; determined predictive power for LV hypertrophy using ROC curves and AUC.
Main Results:
- Agreement varied significantly across BP measurement methods (CCC 0.35-0.94).
- Pre-dialysis BP measurements were the weakest predictors of LV hypertrophy.
- Standardized, post-dialytic, and inter-dialytic measurements showed strong predictive power (AUC 0.79-0.80).
Conclusions:
- A single standardized BP measurement effectively predicts LV hypertrophy, matching the performance of cumulative measurements.
- Pre-dialysis BP measurements are poor predictors of LV hypertrophy.
- Current guidelines recommending pre-dialysis BP measurements warrant re-evaluation.
Background:
Left ventricular (LV) hypertrophy is common among patients on hemodialysis. While a relationship between blood pressure (BP) and LV hypertrophy has been established, it is unclear which BP measurement method is the strongest correlate of LV hypertrophy. We sought to determine agreement between various blood pressure measurement methods, as well as identify which method was the strongest correlate of LV hypertrophy among patients on hemodialysis.
Methods:
This was a post-hoc analysis of data from a randomized controlled trial. We evaluated the agreement between seven BP measurement methods: standardized measurement at baseline; single pre- and post-dialysis, as well as mean intra-dialytic measurement at baseline; and cumulative pre-, intra- and post-dialysis readings (an average of 12 monthly readings based on a single day per month). Agreement was assessed using Lin's concordance correlation coefficient (CCC) and the Bland Altman method. Association between BP measurement method and LV hypertrophy on baseline cardiac MRI was determined using receiver operating characteristic curves and area under the curve (AUC).
Results:
Agreement between BP measurement methods in the 39 patients on hemodialysis varied considerably, from a CCC of 0.35 to 0.94, with overlapping 95% confidence intervals. Pre-dialysis measurements were the weakest predictors of LV hypertrophy while standardized, post- and inter-dialytic measurements had similar and strong (AUC 0.79 to 0.80) predictive power for LV hypertrophy.
Conclusions:
A single standardized BP has strong predictive power for LV hypertrophy and performs just as well as more resource intensive cumulative measurements, whereas pre-dialysis blood pressure measurements have the weakest predictive power for LV hypertrophy. Current guidelines, which recommend using pre-dialysis measurements, should be revisited to confirm these results.
Related Concept Videos
Hypertension III: Clinical Manifestations and Diagnostic Studies
Hypertension and Regulation of Blood Pressure
Pre-Procedural Guidelines for Assessing Blood Pressure
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Heart Failure II: Pathophysiology
Hypertension II: Pathophysiology