Related Experiment Video
Updated: Jun 12, 2026

Characterization and Application of Passive Samplers for Monitoring of Pesticides in Water
Published on: August 3, 2016
Global pilot study of legacy and emerging persistent organic pollutants using sorbent-impregnated polyurethane foam
Susie Genualdi1, Sum Chi Lee, Mahiba Shoeib
1Environment Canada, Science and Technology Branch, Toronto, Ontario M3H 5T4, Canada.
Abstract:
Sorbent-impregnated polyurethane foam (SIP) disk passive air samplers were deployed alongside polyurethane foam (PUF) disk samplers at 20 sites during the 2009 spring sampling period of the Global Atmospheric Passive Sampling (GAPS) Network. The SIP disk samplers consisted of PUF disks impregnated with finely ground XAD-4 resin. The addition of XAD-4 greatly improves the sorptive capacity of the PUF disk samplers for more volatile and polar chemicals, and allows for linear-phase sampling over several weeks for these compounds. The SIP and PUF disks were analyzed for polychlorinated biphenyls (PCBs), neutral polyfluoroalkyl compounds (PFCs), and ionic PFCs. Correlations between sampler-derived air concentrations for PCBs in the PUF and SIP disks samplers were significant (p < 0.05). The SIP disks effectively captured 4-50% more of the low molecular weight PCBs than the PUF disks samplers, and the PUF disks also had limitations for time-weighted passive sampling of neutral PFCs in air. Theoretical uptake curves for PUF disks showed rapid equilibration occurring in just hours for 8:2 FTOH and in a few days for MeFOSE, while theoretical curves for SIP disks showed superior sampling profiles for the neutral PFCs. PFCs were measured on SIP disks at all sites with 8:2 FTOH being the dominant compound detected and urban centers (n = 3) having the highest total neutral PFC concentrations ranging from 51.7 to 248 pg/m(3). A positive correlation was found between the FTOHs and FOSAs/FOSEs (p < 0.001, Pearson correlation) indicating similar contamination sources. The SIP disk appears to be a promising passive air sampler for measuring both emerging and legacy POPs on a global scale. They can also be used as a complement to the PUF disk sampler for capturing broader classes of compounds, or as a replacement for PUF disks entirely, especially when longer than quarterly deployment periods are desired.
More Related Videos
09:04Identifying Per- and Polyfluorinated Chemical Species with a Combined Targeted and Non-Targeted-Screening High-Resolution Mass Spectrometry Workflow
Published on: April 18, 2019
07:06Investigating Long-Distance Transport of Perfluoroalkyl Acids in Wheat via a Split-Root Exposure Technique