Fabrication and comparison of PMN-PT single crystal, PZT and PZT-based 1-3 composite ultrasonic transducers for NDE applications
Related Experiment Video
Updated: Jun 11, 2026

Fabrication and Characterization of Thickness Mode Piezoelectric Devices for Atomization and Acoustofluidics
Published on: August 5, 2020
Ki-Bok Kim1, David K Hsu, Bongyoung Ahn
1Korea Research Institute of Standards and Science, 1 Doroyng-dong Yuseong-gu, Daejeon, South Korea. kimkibok@kriss.re.kr
Abstract:
This paper describes fabrication and comparison of PMN-PT single crystal, PZT, and PZT-based 1-3 composite ultrasonic transducers for NDE applications. As a front matching layer between test material (Austenite stainless steel, SUS316) and piezoelectric materials, alumina ceramics was selected. The appropriate acoustic impedance of the backing materials for each transducer was determined based on the results of KLM model simulation. Prototype ultrasonic transducers with the center frequencies of approximately 2.25 and 5MHz for contact measurement were fabricated and compared to each other. The PMN-PT single crystal ultrasonic transducer shows considerably improved performance in sensitivity over the PZT and PZT-based 1-3 composite ultrasonic transducers.