Related Experiment Video
Updated: Jan 31, 2026

Surgical Treatment of an Endolymphatic Sac Tumor
Published on: May 26, 2023
Increased sensitivity to low concentration gadolinium contrast by optimized heavily T2-weighted 3D-FLAIR to visualize
Shinji Naganawa1, Hisashi Kawai, Michihiko Sone
1Department of Radiology, Nagoya University Graduate School of Medicine, Shouwa-ku, Nagoya, Japan. naganawa@med.nagoya-u.ac.jp
Purpose:
To increase the sensitivity of 3-dimensional fluid-attenuated inversion recovery (3D-FLAIR) to low concentration gadolinium (Gd)-based contrast medium, we optimized sequence parameters on a phantom and evaluated the optimized sequence in patients suspicious for endolymphatic hydrops.
Materials And Methods:
All scans were performed on a 3-tesla magnetic resonance (MR) unit using a 32-channel head coil. We optimized sequence parameters using a phantom filled with diluted Gd and compared the optimized protocol with 3D-FLAIR using conventional turbo spin echo sequence (3D-FLAIR-CONV). Nine patients underwent scanning using the newly optimized sequence and 3D-FLAIR-CONV 4 hours after double-dose administration of intravenous Gd. We subjectively scored separation of endo- and perilymph space and measured contrast-to-noise ratio (CNR) between endo- and perilymph.
Results:
The optimized sequence in the phantom study consisted of: repetition time, 9000 ms; echo time, 540 ms; inversion time, 2400 ms; low constant readout flip angle, 120 degrees in the later part of the echo train. Image contrast became heavily T(2)-weighted (hT(2)W-3D-FLAIR). In patients, we recognized endolymphatic space for both the cochlea and vestibule significantly better by hT(2)W-3D-FLAIR than 3D-FLAIR-CONV (P<0.01). The mean CNR of the new method was also better than that of 3D-FLAIR-CONV (P<0.01).
Conclusions:
The newly optimized hT(2)W-3D-FLAIR was more sensitive than the previous method to low concentration of Gd. Visualization of the endolymphatic space by double-dose administration of intravenous Gd would be more reliable using hT(2)W-3D-FLAIR.
Related Concept Videos
Increasing Function
Weighted Mean
For example, consider the number of goals scored in the matches of a tournament. While computing the average number of goals scored in the tournament, it may be more important to...
Concentration Cells
Consider the following voltaic cell:
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Space Trusses
At the core of a space truss lies the fundamental unit known as the tetrahedron. This structure is composed of six members that form a three-dimensional shape...
State Space Representation
Consider an RLC circuit, a...