Direct measurement of cyclotron coherence times of high-mobility two-dimensional electron gases

X Wang1, D J Hilton, J L Reno

  • 1Department of Electrical and Computer Engineering, Rice University, Houston, Texas 77005, USA.

Optics Express
|July 1, 2010
PubMed

Related Concept Videos

Mass Analyzers: Common Types01:19

Mass Analyzers: Common Types

The quadrupole mass analyzer consists of four cylindrical metal rods arranged in a diamond carrying a DC voltage and a radio-frequency AC voltage. The motion of ions through the quadrupole depends on the field strength, causing only ions of a certain m/z to resonate successfully and strike the detector at a given field strength. Though the transmission rate for these analyzers is high, the exact elemental composition of the sample is not determined because of low resolution; however, they are...
Thomson's e/m Experiment01:19

Thomson's e/m Experiment

In a beam of charged particles created by a heated cathode, the particles move at different speeds. However, many applications need a beam with uniform particle speeds. An arrangement known as a velocity selector uses electric and magnetic fields to pick particles with a particular speed from the beam.
A particle with charge q, speed v, and mass m enters an area from the top, where the magnetic and electric fields are perpendicular both to the particle's motion and to one another. The magnetic...
Magnetic Moment of an Electron01:23

Magnetic Moment of an Electron

Electrons revolving around a nucleus are analogous to a circular current carrying loop. This current produces a magnetic dipole moment proportional to the electron's orbital angular momentum. Since the orbital angular momentum is quantized in terms of the reduced Planck's constant, the dipole moment is quantized in the Bohr Magneton. The value of the Bohr magneton is 9.27 x 10-24 Am2. Electrons also have an intrinsic spin angular momentum, and the associated spin magnetic moment is...
Atomic Emission Spectroscopy: Instrumentation01:22

Atomic Emission Spectroscopy: Instrumentation

The instrumentation of atomic emission spectrometry (AES) involves various components, including atomization devices that convert samples into gas-phase atoms and ions. There are two main types of atomization devices: continuous and discrete atomizers.  Continuous atomizers, like plasmas and flames, introduce samples in a constant stream, while discrete atomizers inject individual samples using syringes or autosamplers. The most common discrete atomizer is the electrothermal atomizer.
2D NMR: Overview of Homonuclear Correlation Techniques01:16

2D NMR: Overview of Homonuclear Correlation Techniques

Homonuclear correlation spectroscopy (COSY) is a powerful technique used in Nuclear Magnetic Resonance (NMR) spectroscopy to study the correlations between nuclei of the same type within a molecule. It provides information about scalar couplings between adjacent nuclei, which helps determine connectivity and structural information. There are several COSY variants, each with its unique strengths and experimental parameters.
COSY90 is the standard two-dimensional (2D) COSY experiment that...
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation01:26

Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation

Inductively coupled plasma (ICP) is the common plasma source used in atomic emission spectroscopy (AES), a technique that detects and analyzes various elements in a sample. This method is often called inductively coupled plasma atomic emission spectroscopy (ICP-AES).
There are three main types of inductively coupled plasma atomic emission spectroscopy  (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used.