Light diffusion in a turbid cylinder. II. Layered case.

André Liemert1, Alwin Kienle

  • 1Institut für Lasertechnologien in der Medizin und Messtechnik, Helmholtzstr.12, D-89081 Ulm, Germany.

Optics Express
|July 1, 2010
PubMed
Summary

This study presents solutions for light diffusion in turbid cylinders, validated by Monte Carlo simulations. A fast time-domain solution was developed for specific conditions, aiding diffuse optics research.

Related Concept Videos

Steady, Laminar Flow in Circular Tubes01:23

Steady, Laminar Flow in Circular Tubes

Hagen-Poiseuille flow describes a viscous fluid's steady, incompressible flow through a cylindrical tube with a constant radius R. This flow profile is often applied to understand fluid transport in narrow channels, such as capillaries. It serves as a foundational example of laminar flow. In this model, cylindrical coordinates (r,θ,z) are used to describe the radial (r), angular (θ), and axial (z) dimensions within the tube. For Hagen-Poiseuille flow, the velocity profile is purely axial,...
Laminar and Turbulent Flow01:07

Laminar and Turbulent Flow

Fluid dynamics is the study of fluids in motion. Velocity vectors are often used to illustrate fluid motion in applications like meteorology. For example, wind—the fluid motion of air in the atmosphere—can be represented by vectors indicating the speed and direction of the wind at any given point on a map. Another method for representing fluid motion is a streamline. A streamline represents the path of a small volume of fluid as it flows. When the flow pattern changes with time, the streamlines...
Phase Contrast and Differential Interference Contrast Microscopy01:26

Phase Contrast and Differential Interference Contrast Microscopy

Phase-Contrast Microscopes
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Imaging Biological Samples with Optical Microscopy01:18

Imaging Biological Samples with Optical Microscopy

Optical microscopy uses optic principles to provide detailed images of samples. Antonie van Leeuwenhoek designed the first compound optical microscope in the 17th century to visualize blood cells, bacteria, and yeast cells. In 1830, Joseph Jackson Lister created an essentially modern light microscope. The 20th century saw the development of microscopes with enhanced magnification and resolution.
In optical microscopy, the specimen to be viewed is placed on a glass slide and clipped on the stage...
Total Internal Reflection Fluorescence Microscopy01:05

Total Internal Reflection Fluorescence Microscopy

Total internal reflection fluorescence microscopy or TIRF is an advanced microscopic technique used to visualize fluorophores in samples close to a solid surface with a higher refractive index, such as a glass coverslip. TIRF only allows fluorophores in proximity to the solid surface to be excited. When light from a medium with a lower refractive index (such as air) hits the glass coverslip at a critical angle, the light undergoes total internal reflection stead of passing through the glass.
Ostwald’s Dilution Law01:25

Ostwald’s Dilution Law

Consider a binary electrolyte AB with a concentration ‘c’ that reversibly dissociates into its constituent ions. The degree of this dissociation is represented by ⍺. This means that the equilibrium concentration of each ionic species can be expressed as ⍺c. As well as this, the fraction of the electrolyte that remains undissociated at equilibrium is given by (1−⍺). The corresponding equilibrium concentration for this undissociated portion is then calculated as (1−⍺)c. For such solutions,...