Abstract:
We examine the projection approximation in the context of propagation-based phase contrast imaging using hard x-rays. Specifically, we consider the case of a cylinder or a rounded edge, as a simple model for the edges of many biological samples. The Argand-plane signature of a propagation-based phase contrast fringe from the edge of a cylinder is studied, and the evolution of this signature with propagation. This, along with experimental images obtained using a synchrotron source, reveals how propagation within the scattering volume is not fully described in the projection approximation's ray-based approach. This means that phase contrast fringes are underestimated by the projection approximation at a short object-to-detector propagation distance, namely a distance comparable to the free-space propagation within the volume. This failure of the projection approximation may become non-negligible in the detailed study of small anatomical features deep within a large body. Nevertheless, the projection approximation matches the exact solution for a larger propagation distance typical of those used in biomedical phase contrast imaging.
Related Concept Videos
X-ray Imaging
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
X-ray Crystallography
Diffraction
Diffraction is the change in the direction of travel experienced by an electromagnetic wave when it encounters a physical barrier whose dimensions are comparable to those of the wavelength of the light. X-rays are electromagnetic radiation with wavelengths about as long as the distance between neighboring...