Related Experiment Video
Updated: Jun 11, 2026

The Nijmegen Hemostasis Assay: Simultaneous Fluorogenic Measurement of Thrombin and Plasmin Generation in a Single Well
Published on: February 27, 2026
Haemorheologic and fibrinolytic activity in Nigerian HIV infected patients
Richard Omoregie1, Judith E Adeghe, Helen O Ogefere
1Department Of Medical Microbiology, School of Medical Laboratory Science, University of Benin Teaching Hospital P.M.B. 1111, Benin City, Edo State, Nigeria. richyomos@yahoo.com
Objective:
Human immunodeficiency virus (HIV)-infected patients, especially those on antiretrovirals are at risk of cardiovascular disease (CVD). The haemorheologic and fibrinolgtic activity of treatment naïve Nigerian HIV-infected patients were investigated.
Methods:
Blood was collected from 50 newly diagnosed treatment naïve HIV-infected patients and 50 apparently healthy HIV seronegative individuals that served as controls. Haematocrit values, plasma and serum viscosity, plasma fibrinogen concentration and euglobin lysis time were determined.
Result:
The mean +/- standard deviation of haematocrit value of HIV infected patients (31.70 +/- 6.33%) was significantly lower (p<0.0001) than those of controls (39.50 +/- 2.43%). The plasma serum viscosity, plasma fibrinogen concentration and euglobin lysis time of HIV-infected patients were significantly higher compared with those of controls (p<0.0001).
Conclusion:
Treatment naive Nigerian HIV-infected patients have a defective blood flow and fibrinolytic system, which may predispose them to CVD.