Related Experiment Video
Updated: Jun 11, 2026

Inactivation of Pathogens via Visible-Light Photolysis of Riboflavin-5′-Phosphate
Published on: April 6, 2022
Inactivation of Campylobacter jejuni by exposure to high-intensity 405-nm visible light
Lynne Elizabeth Murdoch1, Michelle Maclean, Scott J MacGregor
1The Robertson Trust Laboratory for Electronic Sterilisation Technologies, Department of Electronic and Electrical Engineering, University of Strathclyde, 204 George Street, Glasgow, Scotland. lynne.murdoch@strath.ac.uk
Abstract:
Although considerable research has been carried out on a range of environmental factors that impact on the survival of Campylobacter jejuni, there is limited information on the effects of violet/blue light on this pathogen. This investigation was carried out to determine the effects of high-intensity 405-nm light on C. jejuni and to compare this with the effects on two other important Gram-negative enteric pathogens, Salmonella enteritidis and Escherichia coli O157:H7. High-intensity 405-nm light generated from an array of 405-nm light-emitting diodes was used to inactivate the test bacteria. The results demonstrated that while all three tested species were susceptible to 405-nm light inactivation, C. jejuni was by far the most sensitive organism, requiring a total dose of 18 J cm⁻² of 405-nm light to achieve a 5-log₁₀ reduction. This study has established that C. jejuni is particularly susceptible to violet/blue light at a wavelength of 405 nm. This finding, coupled with the safety-in-use advantages of this visible (non-ultraviolet wavelength) light, suggests that high-intensity 405-nm light may have applications for control of C. jejuni contamination levels in situations where this type of illumination can be effectively applied.
Related Concept Videos
Physical Methods for Controlling Microbial Growth: Radiation and Filtration
Physical Methods for Controlling Microbial Growth: Temperature
Stringent Response in E. coli
Chemical Agents for Microbial Control
Methods of Sterilization I: Physical Methods
Steam sterilization uses non-toxic, low-cost moist heat in the form of saturated steam under pressure, which is fast, microbicidal, and sporicidal, and quickly warms and penetrates fabrics. Autoclaves, or steam sterilizers, expose each item to direct steam contact for a predetermined time at the necessary...
Methods of Sterilization II: Chemical Methods
Using chemical sterilization rather than heat to clean out equipment is recommended. It eradicates and removes all bacteria,...

