Related Experiment Video
Updated: Jan 31, 2026

Optimizing Magnetic Force Microscopy Resolution and Sensitivity to Visualize Nanoscale Magnetic Domains
Published on: July 20, 2022
Beta-gamma coincidence counting efficiency and energy resolution optimization by Geant4 Monte Carlo simulations for a
Weihua Zhang1, Pawel Mekarski, Kurt Ungar
1Radiation Protection Bureau of Health Canada, 775 Brookfield Road, AL 6302D1, Ottawa, Ontario, Canada K1A 1C1. weihua_zhang@hc-sc.gc.ca
Abstract:
A single-channel phoswich well detector has been assessed and analysed in order to improve beta-gamma coincidence measurement sensitivity of (131m)Xe and (133m)Xe. This newly designed phoswich well detector consists of a plastic cell (BC-404) embedded in a CsI(Tl) crystal coupled to a photomultiplier tube (PMT). It can be used to distinguish 30.0-keV X-ray signals of (131m)Xe and (133m)Xe using their unique coincidence signatures between the conversion electrons (CEs) and the 30.0-keV X-rays. The optimum coincidence efficiency signal depends on the energy resolutions of the two CE peaks, which could be affected by relative positions of the plastic cell to the CsI(Tl) because the embedded plastic cell would interrupt scintillation light path from the CsI(Tl) crystal to the PMT. In this study, several relative positions between the embedded plastic cell and the CsI(Tl) crystal have been evaluated using Monte Carlo modeling for its effects on coincidence detection efficiency and X-ray and CE energy resolutions. The results indicate that the energy resolution and beta-gamma coincidence counting efficiency of X-ray and CE depend significantly on the plastic cell locations inside the CsI(Tl). The degraded X-ray and CE peak energy resolutions due to light collection efficiency deterioration by the embedded cell can be minimised. The optimum of CE and X-ray energy resolution, beta-gamma coincidence efficiency as well as the ease of manufacturing could be achieved by varying the embedded plastic cell positions inside the CsI(Tl) and consequently setting the most efficient geometry.
Related Concept Videos
Optimal Foraging
What is Energy?
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Free Energy
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Types of Detectors-II

