Identifying Coronary Artery Calcification on Non-gated Computed Tomography Scans
Published on: August 28, 2018
Effect of a standardized radiation dose reduction protocol on diagnostic accuracy of coronary computed tomographic
Troy M LaBounty1, Jonathon Leipsic, G B John Mancini
1Department of Medicine, Weill Cornell Medical College, New York, NY, USA. tml9001@med.cornell.edu
Abstract:
Although numerous strategies for radiation dose decrease in coronary computed tomographic angiography are effective, their combined impact on diagnostic performance is not known. We therefore assessed the effect of a standardized coronary computed tomographic angiographic protocol on diagnostic accuracy. We evaluated 80 consecutive patients from 3 sites with coronary computed tomographic angiography and quantitative coronary angiography. All sites initially used nonstandardized protocols; 2 sites then initiated a standardized protocol, and 1 site continued its nonstandardized protocol as a time-overlapping control. Two blinded readers interpreted coronary computed tomographic angiographic studies; a third obtained consensus. A blinded core laboratory performed quantitative coronary angiography. Each segment was graded as <50% or > or =50% diameter stenosis. Compared to those using nonstandardized protocols (n = 35), studies using standardized protocols (n = 45) had a trend to increased use of prospective gating (p = 0.09), lower voltage (p <0.01), decreased current (p <0.01), and shorter scan length (p <0.01). Median (interquartile range) radiation dose decreased from 5.7 mSv (4.0 to 10.8) to 2.0 mSv (1.3 to 3.4, p <0.001). There were no significant differences in sensitivity (100%, 20 of 20, vs 100%, 18 of 18, p = 1.0), specificity (93%, 14 of 15, vs 85%, 23 of 27, p = 0.61), or accuracy (97%, 34 of 35, vs 91%, 41 of 45, p = 0.27) by patient; sensitivity (83%, 33 of 40, vs 83%, 25 of 30, p = 0.93), specificity (92%, 86 of 93, vs 92%, 134 of 146, p = 0.85), or accuracy (89%, 119 of 133, vs 90%, 159 of 176, p = 0.80) by artery; or sensitivity (80%, 44 of 55, vs 72%, 26 of 36, p = 0.74), specificity (94%, 332 of 353, vs 94%, 499 of 531, p = 0.96), or accuracy (92%, 376 of 408, vs 93%, 525 of 567, p = 0.80) by segment. In conclusion, a standardized dose-decrease protocol for coronary computed tomographic angiography decreases radiation dose without affecting diagnostic performance.
More Related Videos
06:57Semi-Automatic Graphical Tool for Measuring Coronary Artery Spatially Weighted Calcium Score from Gated Cardiac Computed Tomography Images
Published on: September 22, 2023
11:09High-Resolution Cardiac Positron Emission Tomography/Computed Tomography for Small Animals
Published on: December 16, 2022
Related Concept Videos
Imaging Studies for Cardiovascular System V: CT
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Acute Coronary Syndrome III: Diagnostic Studies
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...