Related Experiment Video
Updated: Jun 11, 2026
![Quantitative [18F]-Naf-PET-MRI Analysis for the Evaluation of Dynamic Bone Turnover in a Patient with Facetogenic Low Back Pain](/_next/image?url=https%3A%2F%2Fcloudfront.jove.com%2FCDNSource%2Fteasers%2F58491.jpg&w=3840&q=50)
Quantitative [18F]-Naf-PET-MRI Analysis for the Evaluation of Dynamic Bone Turnover in a Patient with Facetogenic Low Back Pain
Published on: August 8, 2019
Signal interpretation from low-dosage acquisition. An investigation for computed tomographic imaging
1Department of Engineering, Trinity College, 300 Summit St, Hartford, CT 06106, USA. lin.cheng@trincoll.edu
Objectives:
This paper focuses on how we could analyze and interpret filtered back-projection reconstructed signals from low-dose computed tomographic (CT) imaging systems. There exists a growing imbalance between dosage reduction and effective signal interpretation. At the same time, low-dose applications are undergoing alarming growth.
Methods:
This paper interprets filtered back-projection images in low-dose CT systems and details the possible properties of the artifacts. The interpretation leads to design of a new multi-image filtered back-projection approach that allows artifacts to be effectively identified across multiple images. We use this approach as a building block to propose a new reconstruction method that enables effective artifacts reduction and efficient implementation.
Results:
Experiments with both clinical and simulated low-dose images demonstrate the validity and effectiveness of the proposed approach.
Conclusions:
This study discusses a new FBP-based reconstruction approach based on signal interpretation from low-dosage acquisition. This method uses multiple filtered back-projection images from projection subsets to provide clues for distinguishing underlying clinical structure from artifacts. A framework is derived for effective signal interpretation and artifacts reduction. It requires no hardware change and a minimum amount of extra software support compared with current CT systems. Clinical and simulated low-dose CT scans demonstrated effectiveness of the proposed method.
More Related Videos
12:24Computed Tomography-guided Time-domain Diffuse Fluorescence Tomography in Small Animals for Localization of Cancer Biomarkers
Published on: July 17, 2012
09:55Radiosynthesis, Quality Control, and Small Animal Positron Emission Tomography Imaging of 68Ga-Labelled Nano Molecules
Published on: October 4, 2024
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Radiological Investigation I: X-ray and CT
Imaging Studies for Cardiovascular System V: CT