Interobserver reproducibility of the interpretation of I-123 FP-CIT single-photon emission computed tomography
Marianne C Tondeur1, Anne-Sophie Hambye, Sophie Dethy
1Service des Radio-Isotopes, CHU Saint-Pierre, Rue Haute 322, 1000 Bruxelles, Belgium. Marianne_Tondeur@stpierre-bru.be
Objectives:
I-123 ioflupane (FP-CIT) single-photon emission computed tomography is a recognized tool in the diagnosis of Parkinsonian syndromes. In practice, data interpretation relies on visual and semiquantitative analyses. Good interobserver reproducibility is a prerequisite before claiming the robustness of a technique. This study aimed at evaluating interobserver reproducibility of this approach.
Methods:
Thirty nuclear medicine physicians participated in the study. Data included FP-CIT images and semiquantitative measurements of 12 cases, covering a wide spectrum of scintigraphic patterns and for which a 'true' clinical diagnosis based on long-term follow-up was available. Interobserver agreement was defined, for each case, as the highest percentage reached among the three proposed answers with complete agreement arbitrarily set at 80% or more. Variability in an individual observer's sensitivity to assess data as normal, equivocal or abnormal was scored using a three-point scale.
Results:
Response rate was 99.7%. Among the three possible answers,'normal' accounted for 41.2% of the total, 'abnormal' for 49.8% and 'equivocal' for 8.1%. The mean interobserver agreement was 76% (range: 37-100%), with complete agreement being reached only in five cases. The interpretation proposed by most observers accorded to clinical diagnosis in 75% of the cases. Abnormalities of the central nervous system were encountered in all the cases with disagreement between the observer's interpretation and clinical diagnoses. An important variability in the observers' sensitivity was seen.
Conclusion:
In the particular setting of this preliminary study evaluating the reproducibility of FP-CIT single-photon emission computed tomography interpretation in a group of nuclear medicine physicians with various experiences, interobserver agreement was suboptimal. Collegial discussion and standardized interpretation criteria could contribute to an improved reproducibility.
More Related Videos
08:36Multi-Tracer Studies of Brain Oxygen and Glucose Metabolism Using a Time-of-Flight Positron Emission Tomography-Computed Tomography Scanner
Published on: June 7, 2024
08:40Positron Emission Tomography Imaging for In Vivo Measuring of Myelin Content in the Lysolecithin Rat Model of Multiple Sclerosis
Published on: February 28, 2021
Related Concept Videos
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...