Related Experiment Video
Updated: Jan 26, 2026

Construction of Local Field Potential Microelectrodes for in vivo Recordings from Multiple Brain Structures Simultaneously
Published on: March 14, 2022
Whole-brain susceptibility mapping at high field: a comparison of multiple- and single-orientation methods
1Sir Peter Mansfield Magnetic Resonance Centre, School of Physics and Astronomy, University of Nottingham, University Park, Nottingham, UK.
Abstract:
Optimisation and comparison of the performance of three different methods for calculating three-dimensional susceptibility maps of the whole brain from gradient-echo (phase and modulus) image data acquired at 7 T is described. The methods studied are a multiple-orientation method in which image data acquired with the head at several different angles to the main field are combined and two methods which use data acquired at a single orientation: the first of these is based on exclusion of some k-space data from the calculation (through thresholding of the dipolar field kernel), while the second incorporates a regularisation method that is based on using information from the modulus images. The methods were initially optimised via analysis of data from a phantom containing different compartments of known susceptibility. As part of this work, a novel high-pass filtering methodology was introduced to remove background fields from field maps based on phase data. The optimised methods were successfully applied to high-resolution (0.7 mm isotropic) whole-brain modulus and phase data acquired in vivo from five healthy male subjects, 25-30 years of age. The multiple-orientation method yielded high quality susceptibility maps, out-performing the single-orientation methods. Venous blood vessels as well as the substantia nigra and globus pallidus brain regions showed particularly high positive susceptibility offsets relative to surrounding tissue, consistent with high deoxyhemoglobin and non-heme iron content, respectively. To compare the performance of the different methods, regions of interest were drawn in deep grey matter structures and in cortical grey and white matter. The threshold-based approach was fast and simple to use, but underestimated susceptibility differences and showed significant artefacts due to noise amplification in difficult regions of k-space. The regularised single-orientation method yielded contrast dependent on the choice of spatial priors, but demonstrated the potential to yield susceptibility maps of a similar quality to those calculated using data acquired at multiple orientations to the field.
Related Concept Videos
Bioavailability Study Design: Single Versus Multiple Dose Studies
Multiple Comparison Tests
It would be easy to compare two samples using a significance alpha level of 0.05. In other words, there is only one sample pair to be compared. However, it would be difficult to identify a significantly different sample if the number...
Methods of Documentation I: Source-Oriented Records
In an SOR, each discipline involved in patient care maintains a separate medical record section. This record-keeping method enables easy tracking of patient progress and ensures healthcare staff have access to up-to-date information.
Key Attributes include the following:
Renal Drug Clearance: Comparison Between Renal Excretion Methods
Renal clearance is often associated with the renal glomerular filtration rate (GFR), which represents the rate at which plasma is filtered through the glomeruli in the kidney. When drug reabsorption is minimal and there is no active secretion, renal clearance is closely related to the...
The Sense of Self: Reflected Self-Appraisal and Social Comparison
Magnetic Susceptibility and Permeability
When diamagnetic materials are placed under an external magnetic field, the moments opposite to the field are induced. Hence, the susceptibility for diamagnets has a minimal negative value of 10-5–10-6. Since...

