Background:
Isoflavonoids (IFL) may protect against chronic diseases, including cancer. IFL exposure is traditionally measured from plasma (PL), but the reliability of urine is uncertain. We assessed whether IFL excretion in overnight urine (OU) or spot urine (SU) reliably reflects IFLs in PL and the usefulness of the three matrices to determine soy intake compliance.
Methods:
In a randomized, double-blind, placebo-controlled soy intervention trial with 350 postmenopausal women, IFLs (daidzein, genistein, glycitein, equol, O-desmethylangolensin, dihydrodaidzein, dihydrogenistein) were analyzed by liquid chromatography/mass spectrometry in OU, SU, and PL collected at baseline and every 6 months over 2.5 years.
Results:
High between-subject intraclass correlations between all three matrices (median, 0.94) and high between-subject Pearson correlations (median r(OU-PL) = 0.80; median r(SU-PL) = 0.80; median r(OU-SU) = 0.92) allowed the development of equations to predict IFL values from any of the three matrices. Equations developed from a randomly selected 87% of all available data were valid because high correlations were found on the residual 13% of data between equation-generated and measured IFL values (median r(OU-PL) = 0.86; median r(SU-PL) = 0.78; median r(OU-SU) = 0.84); median absolute IFL differences for OU-PL, SU-PL, and OU-SU were 8.8 nmol/L, 10.3 nmol/L, and 0.28 nmol/mg, respectively. All three matrices showed highly significant IFL differences between the placebo and soy intervention group at study end (P < 0.0001) and highly significant correlations between IFL values and counted soy doses in the intervention group.
Conclusions:
OU and SU IFL excretion reflect circulating PL IFL levels in healthy postmenopausal women accurately.
Impact:
Noninvasively-collected urine can be used to reliably determine systemic IFL exposure and soy intake compliance.
More Related Videos
14:39Semi-Targeted Ultra-High-Performance Chromatography Coupled to Mass Spectrometry Analysis of Phenolic Metabolites in Plasma of Elderly Adults
Published on: April 22, 2022
08:44Elucidation of the Material Basis of Yiqi Qingjie Formula Against IgA Nephropathy Using UHPLC-Q-Orbitrap HRMS Integrated with Network Pharmacology
Published on: May 19, 2026
Related Concept Videos
Urine Studies I: Urinalysis
Cancer Prevention
Some...
Physiology of the Genitourinary System III: Urine Concentration and Dilution
Urine Studies II: Urine Culture and Sensitivity Test
Bioavailability Study Design: Absolute Versus Relative Bioavailability
Bioavailability Study Design: Healthy Subjects Versus Patients