Related Experiment Video
Updated: Jun 11, 2026

An Automated Microscopic Scoring Method for the γ-H2AX Foci Assay in Human Peripheral Blood Lymphocytes
Published on: December 25, 2021
Cumulative exposure to ionizing radiation from diagnostic and therapeutic cardiac imaging procedures: a
Jersey Chen1, Andrew J Einstein, Reza Fazel
1Section of Cardiovascular Medicine, Department of Medicine, Yale School of Epidemiology and Public Health, New Haven, Connecticut 06520, USA. jersey.chen@yale.edu
Objectives:
The purpose of this study was to describe radiation exposure from cardiac imaging procedures over time in a general population.
Background:
Cardiac imaging procedures frequently expose patients to ionizing radiation, but their contribution to effective doses of radiation in the general population is unknown.
Methods:
We used administrative claims to identify cardiac imaging procedures performed from 2005 to 2007 in 952,420 nonelderly insured adults in 5 U.S. health care markets. We estimated 3-year cumulative effective doses of radiation in millisieverts from these procedures We then calculated population-based annual rates of radiation exposure to effective doses < or =3 mSv/year (background level of radiation from natural sources), >3 to 20 mSv/year, or >20 mSv/year (upper annual limit for occupational exposure averaged over 5 years).
Results:
A total of 90,121 (9.5%) individuals underwent at least 1 cardiac imaging procedure using radiation. Among patients who underwent > or =1 cardiac imaging procedures, the mean cumulative effective dose over 3 years was 23.1 mSv (range 1.5 to 543.7 mSv). Myocardial perfusion imaging accounted for 74% of the cumulative effective dose. Overall, 47.8% of cardiac imaging procedures were performed in physician offices; this proportion was higher for myocardial perfusion imaging (74.8%) and cardiac computed tomography studies (76.5%). The annual population-based rate of receiving an effective dose of >3 to 20 mSv/year was 89.0 per 1,000; and 3.3 per 1,000 for cumulative doses >20 mSv/year. Annual effective doses increased with age and were generally higher among men.
Conclusions:
Cardiac imaging procedures lead to substantial radiation exposure and effective doses for many patients in the U.S.
More Related Videos
06:02Anatomical Reconstructions of the Human Cardiac Venous System using Contrast-computed Tomography of Perfusion-fixed Specimens
Published on: April 18, 2013
08:13In Vivo Quantitative Assessment of Myocardial Structure, Function, Perfusion and Viability Using Cardiac Micro-computed Tomography
Published on: February 16, 2016
Related Concept Videos
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Imaging Studies for Cardiovascular System V: CT
Biological Effects of Radiation
Radiological Investigation I: X-ray and CT
Imaging Studies for Cardiovascular System IV: CMRI
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion, evaluates...