Related Experiment Video
Updated: Dec 6, 2025

Continuous Venous-Arterial Doppler Ultrasound During a Preload Challenge
Published on: January 20, 2023
Continuous and less invasive central hemodynamic monitoring by blood pressure waveform analysis
1Department of Electrical and Computer Engineering, Michigan State University, East Lansing, Michigan 48824-1226, USA. rama@egr.msu.edu
Abstract:
Blood pressure waveform analysis may permit continuous (i.e., automated) and less invasive (i.e., safer and simpler) central hemodynamic monitoring in the intensive care unit and other clinical settings without requiring any instrumentation beyond what is already in use or available. This practical approach has been a topic of intense investigation for decades and may garner even more interest henceforth due to the evolving demographics as well as recent trends in clinical hemodynamic monitoring. Here, we review techniques that have appeared in the literature for mathematically estimating clinically significant central hemodynamic variables, such as cardiac output, from different blood pressure waveforms. We begin by providing the rationale for pursuing such techniques. We then summarize earlier techniques and thereafter overview recent techniques by our collaborators and us in greater depth while pinpointing both their strengths and weaknesses. We conclude with suggestions for future research directions in the field and a description of some potential clinical applications of the techniques.
More Related Videos
Related Concept Videos
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Measurement of Blood Pressure
Sites for measruring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement

