Related Experiment Video
Updated: Jun 11, 2026

Doppler Ultrasound-Based Leg Blood Flow Assessment During Single-Leg Knee-Extensor Exercise in an Uncontrolled Setting
Published on: December 15, 2023
Reproducibility of blood pressure and inter-beat interval variability in man
M Jíra1, E Závodná, Z Nováková
1Department of Physiology, Faculty of Medicine, Masaryk University, Brno, Czech Republic.
Abstract:
Increased blood pressure variability (BPV) and decreased inter-beat interval (heart rate, respectively) variability (IBIV, HRV respectively) are associated with cardiovascular disorders. The aim of this study was to evaluate the reproducibility of BPV and IBIV (HRV) in young healthy individuals. Blood pressure and inter-beat intervals (instantaneous values of heart rate, respectively) were recorded beat-to-beat at rest (5 min, Finapres, breathing at 0.33 Hz) in 152 subjects (19-24 years) 3 times in periods of one week. Systolic (SBPV(0.1r)/SBPV(0.1a)) and diastolic (DBPV(0.1r)/DBPV(0.1a)) blood pressure variability in relative (r.u.) and absolute (mmHg(2)/Hz) units and inter-beat interval (IBIV(0.1r)/IBIV(0.1a)), or heart rate (HRV(0.1r)/HRV(0.1a)) variability in relative (r.u.) and absolute (ms(2)/Hz, resp. mHz(2)) units were determined by the spectral method as spectral power at the frequency of 0.1 Hz and 0.33 Hz (SBPV(0.33r)/SBPV(0.33a), DBPV(0.33r)/DBPV(0.33a), IBIV(0.33r)/IBIV(0.33a), HRV(0.33r)/HRV(0.33a)). All indices of BPV and IBIV (resp. HRV) revealed a lower intraindividual than interindividual variability (ANOVA; p<0.001). The mean values of all indices in each subject significantly correlated with distribution of individual values in the same subject (Pearson's correlation coefficient; p<0.001). Blood pressure and inter-beat interval (heart rate) variability is an individual characteristic feature.
Related Concept Videos
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Assessment of blood pressure in brachial artery(two-step method)
Measurement of Blood Pressure
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Errors occurring during blood pressure monitoring
Several factors...

