Related Experiment Video
Updated: Jun 11, 2026

Drug-Induced Sleep Endoscopy (DISE) with Target Controlled Infusion (TCI) and Bispectral Analysis in Obstructive Sleep Apnea
Published on: December 6, 2016
Pulse wave analysis in a pilot randomised controlled trial of auto-adjusting and continuous positive airway pressure
Jessie P Bakker1, Angela J Campbell, Alister M Neill
1WellSleep Sleep Investigation Centre, Department of Medicine, University of Otago, Wellington, New Zealand. jessie.bakker@otago.ac.nz
Purpose:
Non-invasive measurements of arterial stiffness including the augmentation index (AIx) and central blood pressure (BP) have been used to assess the cardiovascular health of patients with obstructive sleep apnoea (OSA), a well-established independent risk factor of cardiovascular disease. Continuous positive airway pressure (CPAP) can significantly reduce the AIx, but no studies have analysed the effect of auto-adjusting PAP (APAP) or studied morbidly obese patients with severe OSA at higher risk of cardiovascular disease. In this randomised, single-blinded crossover pilot trial, we aimed to compare the efficacy of CPAP with APAP (ResMed S8 Autoset II) in improving peripheral BP, central BP and the AIx, using SphygmoCor technology.
Methods:
Twelve severe OSA patients (mean±SD; apnoea-hypopnoea index, 75.8 ± 32.7; BMI, 49.9 ± 5.2 kg/m(2)) were consecutively recruited and received CPAP (mean pressure, 16.4 cm H(2)O) or APAP in random order for four nights at home, separated by a four-night washout. Cardiovascular measurements were taken at baseline, post-washout and following each treatment arm.
Results:
The polysomnographically recorded residual apnoea-hypopnoea index and compliance to treatment were not significantly different between arms (p > 0.05). There were no significant differences in peripheral or central BP between arms (p > 0.05). The AIx was lower with CPAP than APAP (by 5.8%), with a large effect size not reaching statistical significance (r = 0.61, p = 0.14).
Conclusion:
The large effect size evident when comparing the AIx following CPAP and APAP indicates the need to perform an adequately powered trial in order to determine if APAP improves arterial stiffness to the same extent as CPAP.