Related Experiment Video
Updated: Jun 10, 2026

Using Near-Infrared Spectroscopy Wearable Devices to Identify Central Versus Peripheral Limitations During Exercise
Published on: December 19, 2024
The distribution of transcutaneous CO2 emission and correlation with the points along the pericardium meridian
Wei-Bo Zhang1, Yu-Ying Tian, Zong-Xiang Zhu
1Institute of Acupuncture and Moxibustion, China Academy of Chinese Medical Science, Beijing, China. zhangweibo@hotmail.com
Abstract:
This study aimed to understand energy metabolism distribution along the pericardium meridian and verify the correlation between the body surface (points), and classic meridian theory. A highly sensitive CO(2) instrument was used to measure the transcutaneous CO(2) emission at 13 points along the pericardium meridian line (12 points on the line and one point beyond the line) and 13 control points beside them. Results showed that the distribution of transcutaneous CO(2) emission is highly related to the position on the body. Transcutaneous CO(2) emission is significantly higher at P7 and P3, than the control points beside them. The points along the meridian and the points beside them were clustered with relative distance by SAS statistics software. Two distance matrixes were then obtained. The correlation coefficients between the points along the line and between the control points were calculated. The results showed that the 13(th) point beyond the line was far from the 12 points on the line (distance, 0.24), while acupoints on the line clustered earlier when compared with the non-acupoints. The average correlation coefficients among the acu-points was 0.65 which was significantly higher than 0.56, among the non-acupoints. No such characteristics were found among the control points. It was concluded that there is a strong correlativity of energy metabolism activity between the body surfaces along the meridian, and an even stronger correlativity between the acupoints on the meridian.
More Related Videos
Related Concept Videos
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this principle...
Correlation between ECG and Cardiac Cycle
A cardiac action potential originates in the SA node and spreads throughout the atria and the AV node in approximately 0.03 seconds. This results in the P wave in an ECG and triggers atrial contraction. The action potential is then briefly slowed at the AV node, allowing the atria to contract and fill the ventricles with blood before...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's forehead...
Electrocardiogram Fundamentals
An electrocardiogram (ECG) is a diagnostic tool for identifying cardiac conditions such as arrhythmias, conduction abnormalities, and myocardial ischemia.
Definition
An electrocardiogram (ECG) visualizes the heart's electrical activity by tracing the electrical movement associated with each heartbeat on a graph or monitor. As the heart beats, an electrical wave passes through it, correlating with the cardiac cycle events.
Parts of an ECG
An ECG utilizes electrodes on the skin to...
Pressure Relationships in Thoracic Cavity
Breathing Mechanisms
Both intra-alveolar and intrapleural pressures rely on specific lung properties. The ability to breathe—allowing air to enter the lungs during...
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above the...

