Related Experiment Video
Updated: Jun 10, 2026

Biomechanical Characterization of Human Soft Tissues Using Indentation and Tensile Testing
Published on: December 13, 2016
Meniscus and cartilage exhibit distinct intra-tissue strain distributions under unconfined compression
1Department of Mechanical Engineering, Stanford University, Stanford, CA 94305-4038, United States.
Objective:
To examine the functional behavior of the surface layer of the meniscus by investigating depth-varying compressive strains during unconfined compression.
Design:
Pairs of meniscus and articular cartilage explants (n=12) site-matched at the tibial surfaces were subjected to equilibrium unconfined compression at 5, 10, 15, and 20% compression under fluorescence imaging. Two-dimensional (2D) deformations were tracked using digital image correlation (DIC). For each specimen, local compressive engineering strains were determined in 200 microm layers through the depth of the tissue. In samples with sharp strain transitions, bilinear regressions were used to characterize the surface and interior tissue compressive responses.
Results:
Meniscus and cartilage exhibited distinct depth-dependent strain profiles during unconfined compression. All cartilage explants had elevated compressive engineering strains near the surface, consistent with previous reports. In contrast, half of the meniscus explants tested had substantially stiffer surface layers, as indicated by surface engineering strains that were ∼20% of the applied compression. In the remaining samples, surface and interior engineering strains were comparable. 2D Green's strain maps revealed highly heterogeneous compressive and shear strains throughout the meniscus explants. In cartilage, the maximum shear strain appeared to be localized at 100-250 microm beneath the articular surface.
Conclusions:
Meniscus was characterized by highly heterogeneous strains during compression. In contrast to cartilage, which consistently had a compliant surface region, meniscal explants were either substantially stiffer near the surface or had comparable compressive stiffness through the depth. The relatively compliant interior may allow the meniscus to maintain a consistent surface contour while deforming during physiologic loading.
More Related Videos
Related Concept Videos
Relation between Poisson's ratio, Modulus of Elasticity and Modulus of Rigidity
Normal Strain under Axial Loading
Deformations in a Symmetric Member in Bending
When the member is segmented into tiny cubic elements, it is observed that the primary stress...
Strain and Elastic Modulus
Bending of Members Made of Several Materials
Hooke's Law determines stress in each material, stating that stress is proportional to strain but varies due to each material's...
Three-Dimensional Analysis of Strain

