Abstract:
An overview of radiological incident involving radiation source from a lightning rod (152Eu/154Eu), together with dose estimation for individuals exposed to ionising radiation is given in the paper. The cause of the incident was an orphaned source from a lightning rod. The dose received by individuals was assessed using a retrospective dosimetry technique, based on the information on behaviour of individuals and results of dose rate measurements in the vicinity of the source. Several people have been exposed to relatively high dose rates for an extended period of time. The conservatively estimated cumulative dose values for two categories of individuals were 50 and 40 mSv, respectively, which are significantly higher than annual dose limit for public exposure of 1 mSv. The need to identify radioactive sources incorporated in radioactive lightning rods, to maintain control and accountability and to remove and dispose of them properly along with appropriate record keeping in Serbia was highlighted. These activities would reduce the probability of occurrence of radiation incidents in Serbia.
Related Concept Videos
Radiological Investigation I: X-ray and CT
Biological Effects of Radiation
X-ray Imaging
Radiation: Applications
The average...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...