Related Experiment Video
Updated: Jun 10, 2026

Clinical Imaging of Microwave Mammography
Published on: November 14, 2025
Comparison of image acquisition and radiologist interpretation times in a diagnostic mammography center
Cherie M Kuzmiak1, Elodia Cole, Donglin Zeng
1Department of Radiology, University of North Carolina Lineberger Comprehensive Cancer Center, University of North Carolina at Chapel Hill, Chapel Hill, NC 27599-7510, USA. cherie_kuzmiak@med.unc.edu
Rationale And Objectives:
The purpose of this study was to determine the acquisition and interpretation times of screen-film mammography and soft-copy digital mammography in a diagnostic mammography center.
Materials And Methods:
The study was conducted in three phases for patients presenting for clinical diagnostic workup to a mammography clinic. In the first phase, technologist acquisition and processing times and radiologist interpretation time were measured for patients imaged with a screen-film mammographic system. During the second phase of the study, times were measured for patients imaged with a direct radiographic digital mammographic system, with interpretation performed on a soft-copy display system. During the third phase, 3 months after installation of the soft-copy display system, times were measured again for patients imaged on the same direct radiographic digital mammographic system, with interpretation with the same soft-copy system. The same four experienced breast imaging radiologists and seven technologists participated in all phases of the study. All data were entered into a database, and statistical analysis was conducted using weighted linear models and logarithmic transformation.
Results:
Times were obtained for 295 patients. There were 100 patients each for phases 1 and 2 and 95 patients for phase 3. Diagnostic mammographic acquisition times with processing were 13.02 min/case for screen film (phase 1), 8.16 min/case for digital (phase 2), and 10.66 min/case for digital (phase 3) (P < .001 and P < .0001, respectively). In addition, the radiologist interpretation time for digital mammography in both phases was not significantly different from that for film mammography (P = .2853 and P = .2893, respectively). There was no significant difference between phases 2 and 3 (P = 1.0000). The mean interpretation times were 3.75 min/case for screen film, 2.14 min/case for digital (phase 2), and 2.26 min/case for digital (phase 3).
Conclusions:
Digital mammography significantly shortened the acquisition time for diagnostic mammography. There was no significant difference in interpretation time compared to screen-film mammography in a diagnostic mammography setting.
More Related Videos
Related Concept Videos
Radiological Investigation I: X-ray and CT
Imaging Studies III: Computed Tomography
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...

