Related Experiment Video
Updated: Jun 10, 2026

A Murine Model of Hemodialysis Access-Related Hand Dysfunction
Published on: May 31, 2022
Haemodialysis decreases finger pressures independent of artificial kidney blood flow
Frank Van Hoek1, Marc R Scheltinga, Saskia Houterman
1Departments of Surgery, Máxima Medical Center-Veldhoven, PO box 7777, 5500 MB Veldhoven, The Netherlands.
Background:
During haemodialysis, some patients experience intensification of symptoms of haemodialysis access-induced distal ischaemia. Aim of this study is to compare the effects of two different regimens of arterial blood flow in patients with an arteriovenous access.
Methods:
A questionnaire identified 10 patients that subjectively experienced ischaemic symptoms during haemodialysis. Systolic blood pressure, heart rate, finger pressure (P(dig)), finger temperature (T(dig)), oxygen saturation and ischaemic scores were monitored during two different arterial blood flow dialysis sessions.
Results:
Before dialysis, P(dig) and T(dig) of the arteriovenous access hand were significantly lower compared with the other hand. Haemodialysis induced a drop of P(dig) in both hands. All changes in P(dig) occurred independent of the artificial kidney's blood flow level.
Conclusion:
Systemic hypotension following onset of haemodialysis further intensifies an already diminished hand perfusion. Measures preventing dialytic hypotension will likely attenuate symptoms associated with haemodialysis access-induced distal ischaemia during haemodialysis.
Related Concept Videos
Hemodialysis I: Introduction
Hemodialysis II: Procedure and Complications
Hemodialysis III: Nursing Management
Dialysis
Acute kidney injury develops suddenly and can be caused by pre-renal causes (e.g., hypovolemia, shock), intrinsic renal causes (e.g., acute tubular necrosis), or post-renal causes (e.g., urinary obstruction). In contrast, chronic renal failure progresses gradually over time and is often...
Dialysis
Acute Kidney Injury V: Interprofessional Care