Related Experiment Video
Updated: Feb 6, 2026

Extraction of Non-Protein Amino Acids from Cyanobacteria for Liquid Chromatography-Tandem Mass Spectrometry Analysis
Published on: December 9, 2022
Development and validation of a liquid chromatography-tandem mass spectrometry method for simultaneous quantification
Chang-Ching Lin1, Chien-Wen Kuo, Li-Heng Pao
1School of Pharmacy, National Defense Medical Center, 9F, 161 Minchuan East Road, Section 6, Taipei, Taiwan, 114, Republic of China.
Abstract:
The first liquid chromatography-tandem mass spectrometry method was developed and validated for the simultaneous quantification of p-aminohippuric acid and inulin, both typical biomarkers of kidney function. 5-(Hydroxymethyl)furfural, generated from inulin by acid and heat preparation, was used as an inulin substitute for the quantification. Acetaminophen was used as the internal standard. Solid-phase extraction was carried out with 5% methanol as the washing solution to optimize the retention of the analytes and to avoid obstruction of the orifice plate of the mass spectrometer caused by any unreacted inulin residue remaining from the sample preparation process. Chromatography separation was performed on a Symmetry C(18) column and a mobile phase composed of 2 mM ammonium formate and 0.1% formic acid in water (solvent A) and 2 mM ammonium formate and 0.1% formic acid in acetonitrile (solvent B) (30:70, v/v). Detection was performed with a triple-quadrupole tandem mass spectrometer using positive ion mode electrospray ionization in the multiple reaction monitoring mode. The selected transitions were m/z 195.2 → 120.2, 127.1 → 109.1, and 152.1 → 110.0 for p-aminohippuric acid, inulin [measured as 5-(hydroxymethyl)furfural], and acetaminophen, respectively. The linearity ranged from 10 to 140 μg/mL and from 100 to 1,400 μg/mL for p-aminohippurric acid and inulin (r > 0.99), respectively. The precisions and accuracies were all within 12 and 11% for the lower limit of quantification and quality control samples, respectively. This application was proven to be reliable and accurate and was successfully applied to a renal function study.
More Related Videos
07:25Quantitative Metabolomics of Saccharomyces Cerevisiae Using Liquid Chromatography Coupled with Tandem Mass Spectrometry
Published on: January 5, 2021
08:56Quantitative Analysis of the Cellular Lipidome of Saccharomyces Cerevisiae Using Liquid Chromatography Coupled with Tandem Mass Spectrometry
Published on: March 8, 2020
Related Concept Videos
Tandem Mass Spectrometry
Serum Studies: Renal Function Tests
Peptide Identification Using Tandem Mass Spectrometry
This technique helps gather information regarding the protein from which the peptide was obtained and to study the peptides’ amino acid sequence. Identifying peptides from a complex mixture is an important component of the growing field of...
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences
Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview