Capillary liquid chromatography with diode array and mass spectrometry detection for heterocyclic aromatic amine
R Gonzalo-Lumbreras1, N Rosales-Conrado, M E León-González
1Analytical Chemistry Department, Faculty of Chemistry, Complutense University of Madrid, Avda. Complutense s/n, E-28040 Madrid, Spain. rakel.gonzalo@quim.ucm.es
Abstract:
In the present paper, we have developed a capillary liquid chromatography with MS detection for the determination at ngg⁻¹ levels of four heterocyclic aromatic amines (MeIQx, norharman, harman and harmine), a group of mutagenic and carcinogenic compounds that can potentially be produced in protein-rich food during processing operations. They have been determined in commercial ready-to-eat (RTE) smoked salmon and soft cheese treated with E-beam irradiation. On the basis of experimental design studies and operating conditions of MS detector, best chromatographic conditions were obtained using a Luna® C¹⁸ capillary column (150 mm × 0.3 mm I.D.) with a mixture of acetonitrile-ammonium formate 5 mM pH 3.6 buffer (13:87, v/v) as mobile phase. To improve sensitivity, large injection volumes (20 μL) and injection solutions of low elution strength were employed. Sample preparation procedure included a previous treatment with 1M NaOH, followed by two solid-phase extraction steps; firstly on diatomaceous earth and then on mixed-mode cartridges. Heterocyclic amines were detected neither in irradiated and in non-irradiated samples, indicating that they were not formed by the radiation effect even at doses higher than those indicated in the Food Safety Objective established by regulatory agencies. RTE food samples were spiked at concentration levels in the range 10-30 ngg⁻¹. Recoveries higher than 85% (n=3 for each spiked level) were obtained, showing the effectiveness of the proposed methodology.
More Related Videos
08:21Determination of Inorganic Arsenic in a Wide Range of Food Matrices using Hydride Generation - Atomic Absorption Spectrometry.
Published on: September 1, 2017
12:47Workflow Based on the Combination of Isotopic Tracer Experiments to Investigate Microbial Metabolism of Multiple Nutrient Sources
Published on: January 22, 2018
Related Concept Videos
High-Performance Liquid Chromatography: Types of Detectors
Gas Chromatography: Types of Detectors-II
Atomic Emission Spectroscopy: Lab
Atomic Absorption Spectroscopy: Lab
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing nebulizer...