Related Experiment Video
Updated: Jun 10, 2026

Assessment of Pulmonary Capillary Blood Volume, Membrane Diffusing Capacity, and Intrapulmonary Arteriovenous Anastomoses During Exercise
Published on: February 20, 2017
Assessment of anaerobic power to verify VO2max attainment
Todd A Astorino1, Ailish C White
1Department of Kinesiology, CSU-San Marcos, San Marcos, CA, USA. astorino@csusm.edu
Abstract:
Across various populations, verification testing is used to confirm VO(2)max attainment and has repeatedly shown similar VO(2)max values to those obtained from incremental exercise. Yet, many individuals show meaningful differences in VO(2)max between protocols, and an explanation for this is unknown. The aim of the study was to elucidate this phenomenon in 30 men and women of similar age, fitness, and physical activity using assessment of anaerobic power. On day 1, they completed the Wingate test, and returned at least 48 h later to complete incremental cycle ergometry followed by a verification protocol. During exercise, ventilation, pulmonary gas exchange data, and heart rate (HR) were continuously measured. Mean VO(2)max was similar (P > 0.05) between protocols (42.05 +/- 5.88 ml kg(-1) per min versus 42.03 +/- 5.75 ml kg(-1) per min, respectively), although seven subjects (23%) revealed a VO(2)max that was not 'verified' by the supramaximal protocol. Indices of power output and gas exchange data were similar (P > 0.05) between subjects who revealed a 'true' VO(2)max compared to those who did not, although peak and mean power was consistently higher in persons whose VO(2)max was not 'verified.' A previously established HRmax criterion for verification testing was not met in 17% of subjects. Additional study is merited to identify alternate determinants of VO(2)max, such as muscle activation via assessment of motor unit recruitment, and to investigate utility of verification testing to confirm VO(2)max attainment in elite athletes and the elderly.
Related Concept Videos
Assessment of Respiration
Subjective Assessment: Nurses interview the patient to gather information directly during the subjective assessment. It includes questions about the individual's medical history, medications, and symptoms, focusing on past respiratory conditions like asthma or COPD,...
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement:
Respiratory Volumes and Capacities
Respiratory Capacities
One key metric is the Inspiratory Capacity (IC), which represents the maximum amount of air that can be inhaled with full effort. IC is calculated by summing the tidal volume and inspiratory reserve volume, typically ranging from 2.4 to 3.6 liters.
The Functional Residual Capacity (FRC) represents the air in the...
Pulmonary Function Tests
Pulmonary Function Tests are crucial diagnostic tools for assessing respiratory function, particularly in patients with chronic respiratory disorders. They comprehensively evaluate lung volumes, ventilatory function, breathing mechanics, diffusion, and gas exchange. These tests help diagnose pulmonary diseases and play a significant role in monitoring disease progression, evaluating disability, and assessing response to therapy.
PFTs involve using a spirometer, a...
