Related Experiment Video
Updated: Jun 10, 2026

Synthesis of Soft Polysiloxane-urea Elastomers for Intraocular Lens Application
Published on: March 8, 2019
Practical protective tools for occupational exposure: 1) double focus spectacles for the aged with highly refracted
S Kurokawa1, S Yabe, A Takamura
1Department of Radiolgy, Koshigaya Municipal Hospital; Higashi-koshigaya, Koshigaya City, Saitama, Japan - sigekuro@air.linkclub.or.jp.
Summary:
Two practical protective tools for occupational exposure for neurointerventional radiologists are presented. The first purpose of this study was to investigate the effectiveness of double focus spectacles for the aged with a highly refracted glass lens (special spectacles for the aged) for radiation protection of the crystalline lens of the eye in comparison with other spectacles on the market, based on the measurement of film density which was obtained by exposure of X-ray through those spectacles. As a result of the film densitometry mentioned above, the effectiveness of special spectacles for the aged in radiation protection was nearly equal to the effectiveness of a goggle type shield which is made with a 0.07 mm lead-equivalent plastic lens. The second purpose of this study was to investigate the effectiveness of the protective barrier, which we remodeled for cerebral angiography or neuroendovascular therapy, for radiation exposure, based on the measurement in a simulated study with a head phantom, and on the measurement of radiation exposure in operaters during procedures of clinical cases. In the experimental study radiation exposure in supposed position of the crystalline lens was reduced to about one third and radiation exposure in supposed position of the gonadal glands was reduced to about one seventh, compared to radiation exposure without employing the barrier. The radiation exposure was monitored at the left breast of three radiologists, in 215 cases of cerebral angiography. Employing the barrier in cerebral angiography, average equivalent dose at the left breast measured 1.49mu Sv during 10 min of fluoroscopy. In three kinds of neuroendovascular therapy in 40 cases, radiation exposure in an operator was monitored in the same fashion and the dose was recorded less than the result reported in previous papers in which any protective barrier have not been employed in the procedure (1,2). As a result, the two above mentioned protective tools are considered practical in clinical usage and very effective to reduce radiation exposure in an operator of interventional neuroradiolgy which may sometimes require many hours to complete the therapy under extended fluoroscopic time. 1) The first topic of this report is double focus spectacles for the aged with a highly refracted glass lens (special spectacles for the aged).
Related Concept Videos
Personal Protective Equipment
PPE Use in Healthcare Settings I: Donning
PPE Use in Healthcare Settings II: Doffing
Transmission-based Precautions II: Airborne and Protective Environment
Airborne precautions:
Use airborne precautions when treating patients known or suspected to have diseases that spread through the air—for example, tuberculosis or measles. These organisms are present in smaller droplets expelled by an infected person and...
Standard Precaution
Hand hygiene is the most crucial means to prevent the transmission of disease. Employers are legally required to provide their workers with personal protective equipment (PPE) to minimize exposure or contact with...
Focusing of Light in the Eye
