X-ray Dose Reduction through Adaptive Exposure in Fluoroscopic Imaging
Published on: September 11, 2011
Evaluation of dose area product vs. patient dose in diagnostic X-ray units
K Kisielewicz1, A Truszkiewicz, S Wach
1Department of Medical Physics, Centre of Oncology Maria Skłodowska - Curie Memorial Institute Kraków Branch, Kraków, Poland. z5kisiel@cyf-kr.edu.pl
Abstract:
Dose Area Product (DAP) meters which measure in units of [Gy*m(2)], are widely used in radiology, fluoroscopy and interventional cardiology X-ray units. However, assessment of the radiological hazard to the patient undergoing a given diagnostic procedure cannot be readily obtained from the measured value of DAP. We also developed simple relationships between Entrance Surface Dose (ESD) and the DAP value measured in air, for different collimator field sizes and patient thickness. To establish these relationships, measurements were performed in a water phantom using high-sensitive thermoluminescent detectors (LiF:Mg,Cu,P) calibrated in terms of Kerma in water. Using these relationships developed for a given X-ray unit, calculations of ESD (in mGy) could be performed on the basis of DAP by the X-Ray unit software itself, if the X-ray unit could also evaluate the Focus-to-Skin Distance (FID), e.g. by ultra-sound techniques.
More Related Videos
06:20Irradiator Commissioning and Dosimetry for Assessment of LQ α and β Parameters, Radiation Dosing Schema, and in vivo Dose Deposition
Published on: March 11, 2021
07:57Positron Emission Tomography-based Dose Painting Radiation Therapy in a Glioblastoma Rat Model using the Small Animal Radiation Research Platform
Published on: March 24, 2022
Related Concept Videos
X-ray Imaging
Biological Effects of Radiation
Radiological Investigation I: X-ray and CT
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...