Related Experiment Video
Updated: Jun 10, 2026

Multiplex Therapeutic Drug Monitoring by Isotope-dilution HPLC-MS/MS of Antibiotics in Critical Illnesses
Published on: August 30, 2018
Voltammetric determination of cefixime in pharmaceuticals and biological fluids
Rajeev Jain1, Vinod K Gupta, N Jadon
1School of Studies in Chemistry, Jiwaji University, Gwalior 474011, India.
Abstract:
Electroreduction and adsorption of cefixime was studied in phosphate buffer by cyclic voltammetry (CV), differential pulse cathodic adsorptive stripping voltammetry (DPCAdSV), and square-wave cathodic adsorptive stripping voltammetry (SWCAdSV) at hanging mercury drop electrode (HMDE). These fully validated sensitive and reproducible cathodic adsorptive stripping voltammetric procedures were applied for the trace determination of the bulk drug in pharmaceutical formulations and in human urine. The optimal experimental parameters were as follows: accumulation potential=-0.1 V (vs. Ag/AgCl, 3M KCl), accumulation time=50s, frequency=140 Hz, pulse amplitude=0.07 V, and scan increment=10 mV in phosphate buffer (pH 2.6). The first peak current showed a linear dependence with the drug concentration over the range of 50 ng ml(-1) to 25.6 μg ml(-1). The achieved limit of detection and limit of quantitation were 3.99 and 13.3 ng ml(-1) by SWCAdSV and 7.98 and 26.6 ng ml(-1) by DPCAdSV, respectively. The procedure was applied to assay the drug in tablets. Applicability was also tested in urine samples. Peak current was linear with the drug concentration in the range of 1 to 60 μg ml(-1) of the urine, and minimum detectability was found to be 12.6 ng ml(-1) by SWCAdSV and 58.4 ng ml(-1) by DPCAdSV.
More Related Videos
11:15Quadruple-Checkerboard: A Modification of the Three-Dimensional Checkerboard for Studying Drug Combinations
Published on: July 24, 2021
09:24Application and Methodology of the Non-destructive 19F Time-domain NMR Technique to Measure the Content in Fluorine-containing Drug Products
Published on: August 22, 2017
Related Concept Videos
Pharmaceutical Alternatives: Stability-Related Therapeutic Nonequivalence
Voltammetric Techniques: Cyclic Voltammetry
Determination of Multiple Dosing Parameters: Steady-State, Minimum and Maximum Concentrations
Coulometry: Overview
Voltammetry: Overview
A voltammetric cell uses three electrodes: a working electrode, a reference electrode, and an auxiliary electrode. The redox reactions occur in the working...
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...