An analytical methodology based on differential pulse voltammetry (DPV) on a glassy carbon electrode and the partial least-squares (PLS-1) algorithm for the simultaneous determination of levodopa, carbidopa and benserazide in pharmaceutical formulations was developed and validated. Some sources of bi-linearity deviation for electrochemical data are discussed and analyzed. The multivariate model was developed as a ternary calibration model and it was built and validated with an independent set of drug mixtures in presence of excipients, according with manufacturer specifications. The proposed method was applied to both the assay and the uniformity content of two commercial formulations containing mixtures of levodopa-carbidopa (10:1) and levodopa-benserazide (4:1). The results were satisfactory and statistically comparable to those obtained by applying the reference Pharmacopoeia method based on high performance liquid chromatography. In conclusion, the methodology proposed based on DPV data processed with the PLS-1 algorithm was able to quantify simultaneously levodopa, carbidopa and benserazide in its pharmaceuticals formulations using a ternary calibration model for these drugs in presence of excipients. Furthermore, the model appears to be successful even in the presence of slight potential shifts in the processed data, which have been taken into account by the flexible chemometric PLS-1 approach.
More Related Videos
08:56Detection of Regulated Ergot Alkaloids in Food Matrices by Liquid Chromatography-Trapped Ion Mobility Spectrometry-Time-of-Flight Mass Spectrometry
Published on: November 22, 2024
10:44Examination of Rapid Dopamine Dynamics with Fast Scan Cyclic Voltammetry During Intra-oral Tastant Administration in Awake Rats
Published on: August 12, 2015
Related Concept Videos
Determination of Multiple Dosing Parameters: Steady-State, Minimum and Maximum Concentrations
Calibration Curves: Linear Least Squares
For data that follow a straight line, the standard method for fitting is the linear...
Determination of Multiple Dosing Parameters: Loading and Maintenance Doses
Drug Concentration Versus Time Correlation
Two pivotal parameters are the minimum effective concentration (MEC) and the minimum toxic concentration (MTC). The MEC is the lowest drug...
Therapeutic Drug Monitoring: Drug Analysis Methods
Measurement of Bioavailability: Pharmacodynamic Methods