[The influence of cryochamber on parameters of blood pressure and pulse]
Beata Szczepanowska-Wołowiec1, Jolanta Dudek, Paulina Wołowiec
1Zakład Medycyny Fizykalnej, Instytut Fizjoterapii, Wydział Nauk o Zdrowiu Uniwersytetu Humanistyczno-Przyrodniczego Jana Kochanowskiego w Kielcach. beatawolowiec@op.pl
Introduction:
The influence of whole body cryotherapy on human body.
Material And Methods:
The study was conducted on a group of 50 patients of the Rehabilitation Ward in Wojewodzki Szpital Zespolony in Kielce suffering from chronic pain as a sequel of degenerative-deformative changes and residing. Physiotherapy consisted of treatments in cryo-chamber and physical exercises.
Results:
The average heart rate in the study group before the treatment amounted to 66.5 beats/min +/- 5.7 after the courses of treatments it constituted to 63.1 beats/min. +/- 3.6 at the significance level p < 0.001. The average value of systolic blood pressure in the study group before treatments accounted for 118.7 mmHg +/- 10.8 after the course of treatments amounted to 119.9 mmHg +/- 11.6 at the significance level p < 0.001.
Conclusion:
The single treatment of the whole body cryotherapy and 10 courses of those combined with physical exercises caused statistically significant reduction in the heart rate and pressure parameters. The downward trend was observed in all courses of treatments conducted in this study.
Related Concept Videos
Measurement of Blood Pressure
Factors affecting Blood pressure
Physiological Factors:
Factors Influencing Heart Rate
Let us explore the significant factors affecting heart rate, including age, body temperature, posture, acute pain, chemical influences,...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessment of blood pressure in brachial artery(two-step method)
Pulse
The pulse serves as a clinical indicator...