Related Experiment Video
Updated: Jun 10, 2026

08:40
Using a Cyclic Ion Mobility Spectrometer for Tandem Ion Mobility Experiments
Published on: January 20, 2022
The concept of spectral accuracy for MS
1Cerno Bioscience,Danbury, CT 06810, USA. yongdong.wang@cernobioscience.com
Analytical Chemistry
|August 6, 2010
Summary
Mass spectrometry (MS) and spectroscopy share surprising similarities. Introducing spectral accuracy alongside mass accuracy unlocks new analytical capabilities in mass spectrometry.
Area of Science:
- Analytical Chemistry
- Spectroscopy
- Mass Spectrometry
Background:
- Mass spectrometry (MS) and spectroscopy are distinct analytical techniques.
- Historical and theoretical examination reveals underlying similarities.
- Traditional understanding differentiates MS from spectroscopy.
Purpose of the Study:
- To highlight the fundamental similarities between mass spectrometry and spectroscopy.
- To introduce the concept of spectral accuracy in mass spectrometry.
- To explore novel capabilities enabled by spectral accuracy.
Main Methods:
- Comparative analysis of historical and theoretical perspectives of MS and spectroscopy.
- Introduction and definition of spectral accuracy.
- Discussion of the implications of spectral accuracy for MS.
Main Results:
- A striking similarity between mass spectrometry and spectroscopy is identified.
- Spectral accuracy is presented as a key development for MS.
- New analytical possibilities in MS are demonstrated through spectral accuracy.
Conclusions:
- Mass spectrometry and spectroscopy are more closely related than commonly perceived.
- Spectral accuracy significantly enhances the capabilities of mass spectrometry.
- The integration of spectral accuracy opens new frontiers in analytical chemistry.
Related Concept Videos
High-Resolution Mass Spectrometry (HRMS)
The resolution of a mass spectrometer depends on the efficiency of separating ions with different ion masses. The mass of an atom is approximated to the sum of the masses of protons and neutrons inside, considering the masses of protons and neutrons as equal. However, the masses of the proton (1.6726 × 10−24 g) and neutron (1.6749 × 10−24 g) are not truly equal. There is a minor error in the expression of atomic masses relative to the simplest atom of hydrogen. For example, the mass of helium...
Tandem Mass Spectrometry
Tandem mass spectrometry is a technique that uses multiple mass analyzers in series to obtain a higher selectivity and reduce chemical noise during analyte detection. Instruments with multiple analyzers separated by an interaction cell enable secondary fragmentation and selected study of the fragment ions.Secondary fragmentations occur in the interaction cell and can be induced by various factors. Fragmentation induced by collision with inert gases, such as N2, Ar, He, etc., is called...
Mass Analyzers: Overview
The mass analyzer is a crucial component of the mass spectrometer. In the ionization chamber, the vaporized sample is bombarded with a high-energy electron beam to generate a radical cation and further fragment into neutral molecules, radicals, and cations. A series of negatively charged accelerator plates accelerate the cations into the mass analyzer. The mass analyzer separates ions according to their mass-to-charge (m/z) ratios and then directs them to the detector. The common types of mass...
NMR Spectrometers: Resolution and Error Correction
When magnetic nuclei in a sample achieve resonance and undergo relaxation, the signal detected in NMR is an approximately exponential free induction decay. Fourier transform of an exponential decay yields a Lorentzian peak in the frequency domain. Lorentzian peaks in an NMR spectrum are defined by their amplitude, full width at half maximum, and position, where the peak width is governed by the spin-spin relaxation time alone. In real experiments, however, the applied magnetic field is rendered...
Aliasing
Accurate signal sampling and reconstruction are crucial in various signal-processing applications. A time-domain signal's spectrum can be revealed using its Fourier transform. When this signal is sampled at a specific frequency, it results in multiple scaled replicas of the original spectrum in the frequency domain. The spacing of these replicas is determined by the sampling frequency.
If the sampling frequency is below the Nyquist rate, these replicas overlap, preventing the original signal...
If the sampling frequency is below the Nyquist rate, these replicas overlap, preventing the original signal...
MALDI-TOF Mass Spectrometry
Mass spectrometry is a powerful characterization technique that can identify and separate a wide variety of compounds ranging from chemical to biological entities, based on their mass-to-charge ratio (m/z). The instruments that allow this detection, known as mass spectrometers, have three components: an ion source, a mass analyzer, and a detector. These spectrometers differ based on the nature of their ion source and analyzers.Matrix-assisted laser desorption ionization (MALDI) is a commonly...

