Related Experiment Video
Updated: Jun 10, 2026

Dermoscopy Aids in the Diagnosis of Discoid Lupus Erythematosus
Published on: May 16, 2025
Skin signs in Ehlers-Danlos syndrome: clinical tests and para-clinical methods
1Department of Rheumatology, Rigshospitalet, University of Copenhagen, Copenhagen, Denmark. lars.remvig@rh.regionh.dk
Objective:
The criteria for Ehlers-Danlos syndrome (EDS) and the hypermobility syndrome (HMS) should be reliable. Examination for general joint hypermobility has high reliability but there is only sparse information on the reliability of skin tests, and no information on the level of normal skin extensibility. The present study aimed to assess skin signs by means of clinical and para-clinical methods.
Methods:
A total of 31 EDS patients and 28 healthy controls were examined blinded and in random order. Inter-examiner analysis of clinical tests for skin extensibility, consistency, scarring, and bruising was performed, followed by analyses of extensibility with the suction cup (SC), consistency with a soft tissue stiffness meter (STSM), and thickness with ultrasonography (US). Semi-quantitative assessment of skin extensibility in healthy controls was incorporated in the tests.
Results:
The clinical analyses demonstrated kappa values of: 0.72 for extensibility, 0.23 for consistency, 0.53 for scarring, and 0.63 for bruising. Skin extensibility measurements in healthy controls (n = 28) were 2.79 and 2.93 cm (mean + 2 SD), respectively, by the two examiners. There were significant differences between patients with classical-type EDS and controls with respect to skin extensibility by SC (4.91 vs. 12.52 kPa/mm) and skin consistency by STSM (0.59 vs. 0.76 N). We found no difference in skin thickness.
Conclusion:
The reproducibility of the clinical skin tests was substantial to good, apart from the consistency measurements. We suggest that skin consistency is withdrawn as a diagnostic criterion. The upper level for normal skin extensibility should be 3 cm. SC and STSM are promising para-clinical methods, but their diagnostic sensitivity and specificity need to be determined.
Related Concept Videos
Rheumatic Heart Disease II: Clinical Manifestations and Diagnostic Studies
Assessment of the Cardiovascular System II: Inspection
Head and Neck
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above the...
Atherosclerosis II: Clinical Manifestations and Diagnostic Tests
Cardiovascular System Abnormal Findings I: Inspection and Palpation
Abnormal findings observed during an inspection