Related Experiment Video
Updated: Jun 10, 2026

Simple In-House Ultra-High Performance Capillary Column Manufacturing with the FlashPack Approach
Published on: December 4, 2021
Fabrication and chromatographic performance of porous-shell pillar-array columns
Frederik Detobel1, Selm De Bruyne, Joris Vangelooven
1Vrije Universiteit Brussel, Department of Chemical Engineering, Belgium.
Abstract:
We report on a new approach to obtain highly homogeneous silica-monolithic columns, applying a sol-gel fabrication process inside a rectangular pillar-array column (1 mm in width, 29 microm in height and 33.75 mm in length) having a cross-sectional area comparable to that of a 200 microm diameter circular capillary. Starting from a silicon-based pillar array and working under high phase-separation-tendency conditions (low poly(ethylene glycol) (PEG)-concentration), highly regular silica-based chromatographic systems with an external porosity in the order of 66-68% were obtained. The pillars, 2.4 microm in diameter, were typically clad with a 0.5 microm shell layer of silica, thus creating a 3.4 microm total outer pillar diameter and leaving a minimal through-pore size of 2.2 microm. After mesopore creation by hydrothermal treatment and column derivatization with octyldimethylchlorosilane, the monolithic column was used for chip-based liquid-chromatographic separations of coumarin dyes. Minimal plate heights ranging between 3.9 microm (nonretaining conditions) and 6 mum (for a retention factor of 6.5) were obtained, corresponding to domain-size-reduced plate heights ranging between 0.7 and 1.2. The column permeability was in the order of 1.3 x 10(13) m(2), lower than theoretically expected, but this is probably due to obstructions induced by the sol-gel process in the supply channels.
Related Concept Videos
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Principles Of Column Chromatography
Silica Gel Column Chromatography: Overview
Polar components tend to bind strongly to the silica gel, causing them to move slowly through the column. In contrast, nonpolar compounds...
Column Efficiency: Plate Theory
A higher number of theoretical plates signifies better column efficiency and improved separation capabilities. Plate height affects bandwidth and separation quality; it is inversely...
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
Types Of Column Chromatography
Gel Filtration Chromatography