A kinetic model of TBP auto-regulation exhibits bistability

Sucheta A Gokhale1, Reema Roshan, Vivek Khetan

  • 1Chemical Engineering and Process Development Division, National Chemical Laboratory, CSIR, Pune 411008, India.

Biology Direct
|August 7, 2010
PubMed
Abstract

Related Concept Videos

Pharmacodynamic Models: Link Model and Systems Pharmacodynamic Model01:14

Pharmacodynamic Models: Link Model and Systems Pharmacodynamic Model

The link model is a fundamental pharmacokinetic-pharmacodynamic (PK–PD) approach to account for delayed drug responses when the observed effect does not immediately correlate with the drug's plasma concentration peak. This delay is mathematically addressed by introducing an effect compartment concentration, Ce, which is kinetically linked to the plasma concentration, Cp, via a first-order rate constant, ke0. The linkage allows for a more accurate prediction of drug effects over time. A...
73
BIBO stability of continuous and discrete -time systems01:24

BIBO stability of continuous and discrete -time systems

System stability is a fundamental concept in signal processing, often assessed using convolution. For a system to be considered bounded-input bounded-output (BIBO) stable, any bounded input signal must produce a bounded output signal. A bounded input signal is one where the modulus does not exceed a certain constant at any point in time.
To determine the BIBO stability, the convolution integral is utilized when a bounded continuous-time input is applied to a Linear Time-Invariant (LTI) system....
1.0K
Control System Problem01:21

Control System Problem

In an open-loop system, such as a basic thermostat, the poles of the transfer function influence the system's response but do not determine its stability. However, when feedback is introduced to form a closed-loop system, such as an advanced thermostat that adjusts heating based on room temperature, stability is governed by the new poles of the closed-loop transfer function.
When forming a closed-loop system, issues can arise if the poles cross into the unstable region, leading to potential...
479
Mechanistic Models: Overview of Compartment Models01:21

Mechanistic Models: Overview of Compartment Models

Mechanistic models, a category encompassing both physiological and compartmental modeling, differ from empirical models' approaches to incorporating known factors about the systems being modeled. Empirical models describe data with minimal assumptions, while mechanistic models aim to provide a robust description of available data by specifying assumptions and integrating known factors about the system. Compartmental analysis is a key example of a mechanistic model in pharmacokinetics and...
465
Time-Domain Interpretation of PD Control01:07

Time-Domain Interpretation of PD Control

Proportional-Derivative (PD) control is a widely used control method in various engineering systems to enhance stability and performance. In a system with only proportional control, common issues include high maximum overshoot and oscillation, observed in both the error signal and its rate of change. This behavior can be divided into three distinct phases: initial overshoot, subsequent undershoot, and gradual stabilization.
Consider the example of control of motor torque. Initially, a positive...
430
Pole and System Stability01:24

Pole and System Stability

The transfer function is a fundamental concept representing the ratio of two polynomials. The numerator and denominator encapsulate the system's dynamics. The zeros and poles of this transfer function are critical in determining the system's behavior and stability.
Simple poles are unique roots of the denominator polynomial. Each simple pole corresponds to a distinct solution to the system's characteristic equation, typically resulting in exponential decay terms in the system's...
1.2K