Related Experiment Video
Updated: Jun 10, 2026

Combining Volumetric Capnography And Barometric Plethysmography To Measure The Lung Structure-function Relationship
Published on: January 8, 2019
Regional tidal ventilation and compliance during a stepwise vital capacity manoeuvre
Peter A Dargaville1, Peter C Rimensberger, Inéz Frerichs
1Department of Paediatrics, Royal Hobart Hospital and University of Tasmania, Liverpool Street, Hobart, TAS, 7000, Australia. peter.dargaville@dhhs.tas.gov.au
Purpose:
To determine whether, during mechanical ventilation, an optimal positive end-expiratory pressure (PEEP) can be identified by measurement of regional tidal volume and compliance [V (T(reg)), C (RS(reg))].
Methods:
Sixteen anaesthetized intubated neonatal piglets underwent a stepwise vital capacity manoeuvre performed during pressure control ventilation, with 5 cmH₂O PEEP increments to 25 cmH₂O, and decrements to 0 cmH₂O. Peak inflating pressure was 10 cmH₂O above PEEP throughout. The manoeuvre was performed in the normal lung, after repeated saline lavage and after surfactant therapy. Global V (T) and C (RS) were measured at the airway opening; V (T(reg)) and C (RS(reg)) were measured in the ventral, medial and dorsal lung using electrical impedance tomography (EIT).
Results:
Most uniform distribution of regional tidal ventilation was noted during PEEP decrements after lung recruitment, at varying PEEP levels. In the lavaged and surfactant-treated lung the PEEP optimal for ventilation distribution was also associated with highest mean V (T(reg)) [lavaged: 95 ± 9.3% of maximum, mean ± standard deviation (SD); surfactant-treated: 92 ± 17%] and global V (T) (96 ± 10%; 96 ± 15%). Regional C (RS) plots clearly demonstrated co-existent ventral overdistension and dorsal recruitment, particularly during PEEP increments; whereas during PEEP decrements, peak C (RS(reg)) values showed considerable interregional concordance [e.g. peak C (RS(reg)) in the lavaged left lung; ventral: 0.017 ± 0.0036; medial: 0.016 ± 0.0054; dorsal: 0.017 ± 0.0073 cmH₂O⁻¹; P = 0.98, analysis of variance (ANOVA)].
Conclusions:
After lung recruitment, a PEEP level can be identified by EIT at which tidal ventilation is uniformly distributed, with associated concordance in compliance between lung regions. Bedside monitoring of regional tidal ventilation and compliance using EIT may thus aid in PEEP selection.
Related Concept Videos
Respiratory Volumes and Capacities I
Respiratory Volumes and Capacities
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Factors Affecting Pulmonary Ventilation
Alveolar Surface Tension
The alveolar fluid lines the luminal surface of the alveoli and exerts a force called surface tension. This force is caused by the polar water molecules in the liquid being more strongly attracted to each...
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement:
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation: