Quantitative Detection of Trace Explosive Vapors by Programmed Temperature Desorption Gas Chromatography-Electron Capture Detector
Published on: July 25, 2014
Development and application of a milli-whistle for use in gas chromatography detection
Cheng-Huang Lin1, Chien-Hung Lin, Yi-Shiuan Li
1Department of Chemistry, National Taiwan Normal University, 88 Sec. 4, Tingchow Road, Taipei, Taiwan. chenglin@ntnu.edu.tw
Abstract:
A simple milli-whistle was developed for the use in GC (gas chromatography) detection, in which, compared to a thermal conductivity detector (TCD), 1 order of magnitude superior sensitivity can be obtained. The milli-whistle can be connected to the outlet of a GC capillary. The gas and makeup gas passing through the capillary produces a sound as it passes through the milli-whistle (i.e., the gas of the GC eluate). The sound can easily be detected by a microphone, which, after a Fourier transform (FT) by means of a LabVIEW (Laboratory Virtual Instrumentation Engineering Workbench) built-in program, a very sharp frequency peak (full width at half-maximum, approximately 1.6 Hz) can be simultaneously observed. As a result, GC elutes can be qualitatively determined on the basis of their retention times, and a quantitative analysis can be achieved on the basis of the frequency shifts. When the makeup and carrier gases used were nitrogen, in the case of gas samples, including hydrogen, helium, argon, and carbon dioxide, the limits of detection were found to be approximately 3 microL/each injection; in the case of liquid samples, including methanol, cyclohexane, tetrahydrofuran, hexane, and acetone, the limits of detection were determined to be approximately 10 microg/each injection, respectively. When the gases were changed to hydrogen, the limits of detection were dramatically improved. When acetone was selected as the model sample, a linear relationship was found in the range of 0.2-200 microg/injection.
More Related Videos
08:07A Two-Step Pyrolysis-Gas Chromatography Method with Mass Spectrometric Detection for Identification of Tattoo Ink Ingredients and Counterfeit Products
Published on: May 22, 2019
08:37Measurement of H2S in Crude Oil and Crude Oil Headspace Using Multidimensional Gas Chromatography, Deans Switching and Sulfur-selective Detection
Published on: December 10, 2015
Related Concept Videos
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Gas Chromatography: Types of Detectors-II
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Gas Chromatography: Sample Injection Systems
Two primary injection methods are used...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a column.