Related Experiment Video
Updated: Jun 10, 2026

Spinal Sonography for Ultrasound-Guided Lumbar Neuraxial Anesthesia
Published on: January 31, 2025
Ultrasound decreases the failed labor epidural rate in resident trainees
M C Vallejo1, A L Phelps, S Singh
1Magee-Womens Hospital, Department of Anesthesiology, University of Pittsburgh, Pittsburgh, PA, USA. vallejomc@anes.upmc.edu
Background:
Epidural analgesia is widely used for pain relief during labor. The purpose of this study was to determine if ultrasound measurement of the depth from skin to epidural space before the epidural technique decreases the failure rate of labor analgesia. A secondary objective was to correlate ultrasound depth to the epidural space with actual depth of the needle at placement.
Methods:
In this prospective, randomized, non-blinded study, 370 parturients requesting labor epidural analgesia were randomized to receive their epidural technique by first year anesthesia residents with or without prior ultrasound determination of epidural space depth. Outcome variables included the incidence of epidural catheter replacement for failed analgesia and the number of epidural attempts and accidental dural punctures.
Results:
The ultrasound group had fewer epidural catheter replacements (P<0.02), and epidural placement attempts (P<0.01) compared to the control group. Pearson's correlation coefficients comparing the actual versus ultrasound estimated depth to the epidural space in the longitudinal median and transverse planes were 0.914 and 0.909, respectively. Pearson's correlation coefficient comparing the ultrasound estimated depths to the epidural space in the transverse and longitudinal median planes was 0.940. No significant differences were noted with respect to staff interventions, top-ups, accidental dural punctures, and delivery outcome.
Conclusions:
Ultrasound measurement of the epidural space depth before epidural technique placement decreases the rate of epidural catheter replacements for failed labor analgesia, and reduces the number of epidural attempts when performed by first year residents and compared to attempts without ultrasound guidance.
Related Concept Videos
Local Anesthetics: Clinical Application as Epidural Anesthesia
Since epidural anesthetics can be infused through an epidural catheter, all types of drugs, including short-acting ones, can be administered. Chloroprocaine and lidocaine are examples of short and long-duration anesthetics, respectively. Bupivacaine...
Ultrasound I: Abdominal Ultrasonography
Abdominal ultrasonography, commonly known as abdominal ultrasound, is a vital, non-invasive medical imaging technique widely used in healthcare.
Procedure:
This diagnostic tool allows the clinician to visually inspect internal structures within the abdomen, including vital organs such as the liver, gallbladder, pancreas, kidneys, and spleen.
The abdominal ultrasound process begins with applying a special gel to the patient's skin over the abdomen. This gel enhances the...
Ultrasonography
During an ultrasonography procedure, a handheld device called a...
Local Anesthetics: Clinical Application as Spinal Anesthesia