Related Experiment Video
Updated: Jun 10, 2026

11:57
Measuring Spatially- and Directionally-varying Light Scattering from Biological Material
Published on: May 20, 2013
Spectral shift due to source correlation in conventional spectroradiometric measurements
Applied Optics
|August 12, 2010
Summary
This study analyzes errors in spectroradiometric measurements. It considers spectral shifts caused by source correlation during light propagation, impacting measurement accuracy.
Area of Science:
- Optics and Photonics
- Metrology
Background:
- Recent research highlights spectral shifts in light propagation due to source correlation.
- These shifts can affect optical measurements.
Purpose of the Study:
- To investigate and quantify potential errors in spectroradiometric measurements.
- To understand the impact of correlated light sources on spectral analysis.
Main Methods:
- Theoretical analysis of light propagation with correlated sources.
- Simulations of spectroradiometric measurement scenarios.
- Error analysis based on spectral shift calculations.
Main Results:
- Identified specific error sources in spectroradiometry linked to source correlation.
- Quantified the magnitude of spectral shift-induced errors.
- Demonstrated dependence of errors on correlation properties.
Conclusions:
- Source correlation is a critical factor affecting spectroradiometric accuracy.
- Accounting for spectral shifts is essential for precise light measurements.
- Recommendations for mitigating errors in spectroradiometric applications.
Related Concept Videos
Spectrophotometry: Introduction
Spectrophotometry is the quantitative measurement of the absorption, reflection, diffraction, or transmission of electromagnetic radiation through a material as a function of the intensity and wavelength of the radiation. A spectrophotometer is a device used to measure the change in the radiation intensity caused by its interaction with the material.
The essential components of a spectrophotometer include a source of electromagnetic radiation, a slot for placing a material to be analyzed, and a...
The essential components of a spectrophotometer include a source of electromagnetic radiation, a slot for placing a material to be analyzed, and a...
NMR Spectroscopy: Chemical Shift Overview
The position of the absorption signal of a sample is reported relative to the position of the signal of tetramethylsilane (TMS), which is added as an internal reference while recording spectra. The difference between the absorption frequencies of the sample and TMS (in Hz) is divided by the spectrometer operating frequency (in MHz) to obtain a dimensionless quantity called the chemical shift. It is reported on the δ (delta) scale and expressed in parts per million.
For instance, the proton...
For instance, the proton...
IR Spectrometers
There are two main infrared (IR) spectrophotometers: dispersive IR spectrometers and Fourier transform infrared (FTIR) spectrometers. In a dispersive IR spectrometer, a beam of infrared radiation produced by a hot wire is divided into two parallel equal-intensity beams using mirrors. One beam passes through the sample, while another is a reference beam. The beams then move through the monochromator, which separates the radiations into a continuous spectrum of different frequencies. The...
IR Spectrum Peak Splitting: Symmetric vs Asymmetric Vibrations
Identical bonds within a polyatomic group can stretch symmetrically (in-phase) or asymmetrically (out-of-phase). Similar to hydrogen bonding, these vibrations also influence the shape of the IR peak. Generally, asymmetric stretching frequencies are higher than symmetric stretching frequencies. For example, primary amines exhibit two distinct IR peaks between 3300–3500 cm−1 corresponding to the symmetric and asymmetric N-H stretching, while secondary amines exhibit a single stretching vibration...
Attenuated Total Reflectance (ATR) Infrared Spectroscopy: Overview
Attenuated total reflectance (ATR) infrared spectroscopy is a powerful analytical technique used to study the composition of materials. It is widely employed in chemistry, materials science, forensic science, and other fields where sample characterization is required. ATR has several advantages over traditional transmission IR spectroscopy, including the requirement of little to no sample preparation and the ability to analyze a wide range of samples.
The ATR process begins by directing a beam...
The ATR process begins by directing a beam...
UV–Vis Spectrometers
The absorbance of UV and visible (UV–visible) radiations is measured using a UV–visible spectrophotometer. Deuterium lamps, which emit UV radiation, and tungsten lamps, which produce radiation in the visible region, are used as light sources in UV–visible spectrophotometers. A monochromator or prism is used for diffraction grating, i.e., to split the incoming radiation into different wavelengths. A system of slits is used to focus the desired wavelength on the sample cell. Samples for...

