Implantation of Combined Telemetric ECG and Blood Pressure Transmitters to Determine Spontaneous Baroreflex Sensitivity in Conscious Mice
Published on: February 14, 2021
New method to measure and improve consistency of baroreflex sensitivity values
Luciano Bernardi1, Giacomo De Barbieri, Milla Rosengård-Bärlund
1Department of Internal Medicine, Pavia University, Pavia, Italy. lbern1ps@unipv.it
A new, simple method for measuring baroreflex sensitivity (BRS) shows reliable results and better standardization. High-pass filtering improves agreement between BRS measurement methods, enhancing clinical trial comparability.
Area of Science:
- Cardiovascular Physiology
- Biomedical Engineering
- Clinical Diagnostics
Background:
- Baroreflex sensitivity (BRS) is a crucial prognostic indicator in cardiovascular diseases.
- Current BRS measurement methods lack standardization and often yield conflicting results, hindering clinical application.
- The need for a reliable, standardized BRS assessment is critical for accurate cardiovascular risk stratification.
Purpose of the Study:
- To evaluate a novel, simple ratio of RR interval to systolic blood pressure variability as a reliable BRS measure.
- To compare the agreement of this new method with six established BRS assessment techniques.
- To determine if high-pass filtering improves the concordance among different BRS measurement methods.
Main Methods:
- 1,409 subjects were analyzed, comparing 6 established BRS methods with a new variability ratio method.
- Measurements were taken supine and during head-up tilting in 1,175 subjects.
- Data underwent linear detrending and high-pass filtering at 0.025 and 0.05 Hz.
Main Results:
- The new method demonstrated the best agreement with the median of all tested methods (0.04 ± 0.06 ms/mmHg).
- High-pass filtering significantly improved inter-method agreement (p < 0.001) without compromising sensitivity to physiological challenges.
- The novel method provided BRS estimates across all 2,584 analyzed files, unlike other methods.
Conclusions:
- The proposed simple ratio method offers a robust, reliable, and easily standardized BRS estimate, reflecting the consensus of other methods.
- Routine application of high-pass filtering in BRS analysis can enhance comparability and standardization in clinical trials.
- These advancements facilitate more consistent and dependable BRS assessments for cardiovascular disease management.
More Related Videos
11:08Novel Approach for Simultaneous Recording of Renal Sympathetic Nerve Activity and Blood Pressure with Intravenous Infusion in Conscious, Unrestrained Mice.
Published on: February 14, 2018
14:09Tilt Testing with Combined Lower Body Negative Pressure: a "Gold Standard" for Measuring Orthostatic Tolerance
Published on: March 21, 2013
Related Concept Videos
Assessment of blood pressure in brachial artery(two-step method)
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Measurement of Blood Pressure
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.