Increase of signal-to-noise of more than 10,000 times in liquid state NMR
Jan H Ardenkjær-Larsen1, Klaes Golman, Andreas Gram
1Amersham Health R&D AB, P.A. Hanssonsväg 41, SE-205 12 Malmö, Sweden.
Abstract:
Extract: Two major applications exist for Nuclear Magnetic Resonance (NMR): spectroscopy and imaging. NMR spectroscopy has gained acceptance as one of the major analytical techniques, due to the detailed information that can be obtained about molecular structure, dynamics and intra- and inter-molecular interactions. Magnetic resonance imaging (MRI) is a non-invasive technique with superior soft tissue contrast and broad diagnostic value. The technique has gained wide clinical acceptance and is of great importance in diagnostic medicine. However, despite significant technological advancements (increasing field strength and cooling of electronics), the application of NMR is limited by an intrinsically low sensitivity, as compared to other analytical methods. Fundamentally, the low sensitivity originates from the low magnetic energy of nuclear spins, compared to the thermal energy at room temperature. At a magnetic field strength of 1.5 Tesla and room temperature, the proton spins are polarized to only 5 parts per million, and an improvement of 200,000 is thus theoretically possible. For other nuclei bearing lower magnetic moments (1/4 for 13C and 1/10 for 15N, respectively, compared to 1H), the theoretical enhancement factor is proportionally greater. The weak nuclear polarization is generally compensated by a high concentration (i.e., a large number of nuclear spins). However, the sensitivity of several other nuclei is further reduced by the low natural abundance of the NMR-active isotope (1.1 % for 13C and 0.36 % for 15N, respectively).
Related Concept Videos
¹H NMR: Interpreting Distorted and Overlapping Signals
As Δν decreases and the signals move closer, the doublets appear increasingly distorted. The intensities of the inner lines increase at the cost of those of the outer lines as the signals are slanted or...
Chemical Shift: Internal References and Solvent Effects
The internal reference compound generally used in NMR spectroscopy is tetramethylsilane (TMS). TMS is preferred because it is chemically inert, soluble in NMR solvents, and easily removable. Also, the highly shielded methyl protons in TMS yield an intense...
NMR Spectroscopy: Chemical Shift Overview
For instance, the proton...
¹H NMR Signal Integration: Overview
¹³C NMR: ¹H–¹³C Decoupling
A broadband decoupling technique is used to simplify these complex, sometimes overlapping, signals. Broadband decoupling relies on a...
NMR Spectrometers: Resolution and Error Correction