A long-term clinical evaluation of autoflow during assist-controlled ventilation: a randomized controlled trial
Sigismond Lasocki1, Françoise Labat, Gaetan Plantefeve
1Réanimation Chirurgicale, CHU Bichat, 46 rue Henri Huchard, 75018 Paris, France. sigismond@lasocki.com
Background:
Many new mechanical ventilation modes are proposed without any clinical evaluation. "Dual-controlled" modes, such as AutoFlow™, are supposed to improve patient- ventilator interfacing and could lead to fewer alarms. We performed a long-term clinical evaluation of the efficacy and safety of AutoFlow during assist-controlled ventilation, focusing on ventilator alarms.
Methods:
Forty-two adult patients, receiving mechanical ventilation for more than 2 days with a Dräger Evita 4 ventilator were randomized to conventional (n = 21) or AutoFlow (n = 21) assist-controlled ventilation. Sedation was given using a nurse-driven protocol. Ventilator-generated alarms were exhaustively recorded from the ventilator logbook with a computer. Daily blood gases and ventilation outcome were recorded.
Results:
A total of 403 days of mechanical ventilation were studied and 45,022 alarms were recorded over a period of 8074 hours. The course of respiratory rate, minute ventilation, Fio(2), positive end-expiratory pressure, Pao(2)/Fio(2), Paco(2), and pH and doses and duration of sedation did not differ between the 2 groups. Outcome (duration of mechanical ventilation, ventilator-associated pneumonia, course of Sequential Organ Failure Assessment score, or death) was not different between the 2 groups. The number of alarms per hour was lower with AutoFlow assist-controlled ventilation: 3.3 [1.5 to 17] versus 9.1 [5 to 19], P < 0.0001 (median [quartile range]). In multivariate analysis, a low alarm rate was associated with activation of AutoFlow and a higher midazolam dose.
Conclusions:
This first long-term clinical evaluation of the AutoFlow mode demonstrated its safety with regard to gas exchange and patient outcome. AutoFlow also allowed a very marked reduction in the number of ventilator alarms.
Related Concept Videos
Chronic Obstructive Pulmonary Disease-IV: Assessement and Diagnostic Studies
Medical History
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation (NIPPV)
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Ventilatory Modes
There are three ventilatory modes: full support, partial support, and spontaneous. These are described below.
Full Support Modes
Full support modes include controlled mechanical ventilation, continuous mandatory...
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement:
Cardiopulmonary Resuscitation II: ACLS Airway Management