Related Experiment Video
Updated: Jun 10, 2026

Positron Emission Tomography Imaging for In Vivo Measuring of Myelin Content in the Lysolecithin Rat Model of Multiple Sclerosis
Published on: February 28, 2021
Brain single photon emission computed tomography with Tc-99m MIBI or Tc-99m ECD in comparison to MRI in multiple
Majid Assadi1, Hooman Salimipour, Mohammad Seyedabadi
1Bushehr Research Center for Nuclear Medicine, The Persian Gulf Biomedical Sciences Institute, Bushehr University of Medical Sciences, Bushehr, Iran. assadipoya@yahoo.com
Purpose:
To evaluate whether or not brain single photon emission computed tomography (SPECT) with Tc-99m MIBI or Tc-99m ECD (ethyl cysteinate dimer) can detect any abnormality in patients with definite multiple sclerosis (MS). We then compared these values with the results of T1, T2, and fluid-attenuated inversion recovery in magnetic resonance imaging (MRI).
Materials And Methods:
A total of 16 patients with proved MS were enrolled in the study, and the MRI with and without gadolinium contrast and also brain SPECT with Tc-99m MIBI (8 cases) or Tc-99m ECD (8 other cases) were performed.
Results:
MRI studies was performed in 16 patients (13 women and 3 men, aged 16-38 years) and an average of 10.47, 3.7, 5.3, 1.7, and 0.9 lesions was found in respect in periventricular white matter, juxtacortical white matter, corpus callosum, cerebellar peduncles, and brainstem, whereas brain SPECT with Tc-99m MIBI or Tc-99m ECD detected no abnormality. In addition, 6 cases had some degree of contrast enhancement.
Conclusions:
It seems that brain SPECT with Tc-99m MIBI or Tc-99m ECD would not improve this insufficiency. The small sizes of some plaques, particularly in chronic atrophic form of lesions, and the possibility of deeper anatomic positions of plaques can explain to some extent why the MS lesions were impossible to delineate on brain scan, although additional studies are needed.
Related Concept Videos
Magnetic Resonance Imaging
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Brain Imaging
These technologies include computerized axial tomography (CAT or CT scans), positron-emission tomography (PET scans), magnetic resonance imaging (MRI), functional magnetic resonance imaging (fMRI), and Transcranial Magnetic Stimulation (TMS).
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies for Cardiovascular System IV: CMRI

