Measurement of Ultrafast Vibrational Coherences in Polyatomic Radical Cations with Strong-Field Adiabatic Ionization
Published on: August 6, 2018
Resonant two-photon ionization spectroscopy of jet-cooled tantalum carbide, TaC
Olha Krechkivska1, Michael D Morse
1Department of Chemistry, University of Utah, Salt Lake City, Utah 84112, USA.
Abstract:
The optical spectrum of diatomic TaC has been investigated for the first time, with transitions recorded in the range from 17,850 to 20,000 cm(-1). Six bands were rotationally resolved and analyzed to obtain ground and excited state parameters, including band origins, upper and lower state rotational constants and bond lengths, Fermi contact parameter b(F) for the ground state, and lambda doubling parameters for the excited states. The ground state of TaC was found to be X (2)Sigma(+), originating from the 1sigma(2)2sigma(2)1pi(4)3sigma(1) electronic configuration, in which only the valence orbitals arising from the Ta(5d+6s) and C(2s+2p) orbitals are listed. All of the rotationally resolved and analyzed bands were found to originate from the ground state, giving B(0)"=0.489 683(83) cm(-1), r(0)"=1.749 01(15) A, and b(F)"=0.131 20(36) cm(-1) (1sigma error limits) for (181)Ta (12)C. Comparison of the Fermi contact parameter to the atomic value shows that the 3sigma orbital is approximately 75% Ta 6s in character. The other group 5 transition metal carbides, VC and NbC, have long been known to have 1sigma(2)2sigma(2)1pi(4)1delta(1), (2)Delta ground states, with low-lying 1sigma(2)2sigma(2)1pi(4)3sigma(1), (2)Sigma(+) excited states. The emergence of a different ground state in TaC, as compared to VC and NbC, is due to the relativistic stabilization of the 6s orbital in Ta. This lowers the energy of the 6s-like 3sigma orbital in TaC, causing the 1sigma(2)2sigma(2)1pi(4)3sigma(1), (2)Sigma(+) state to fall below the 1sigma(2)2sigma(2)1pi(4)1delta(1), (2)Delta state.
More Related Videos
Related Concept Videos
Atomic Absorption Spectroscopy: Atomization Methods
Tandem Mass Spectrometry
Atomic Absorption Spectroscopy: Instrumentation
The atomizer used in AAS can be either a flame atomizer or an...
Atomic Absorption Spectroscopy: Radiation and Light Sources
Two common narrow-range 'line' sources used in AAS are hollow-cathode lamps (HCLs) and...
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used.
Inductively Coupled Plasma Atomic Emission Spectroscopy: Principle
The ions and electrons produced interact with the fluctuating magnetic field created by a water-cooled...