Breast MRI as an adjunct to mammography: Does it really suffer from low specificity? A retrospective analysis
Matthias Benndorf1, Pascal A T Baltzer, Tibor Vag
1Institute of Diagnostic and Interventional Radiology, Friedrich-Schiller-University, Jena, Germany. matthias.benndorf@uni-jena.de
Background:
Reports on the specificity of breast MRI are heterogeneous, depending on the respective setting of the performed study.
Purpose:
To retrospectively estimate the sensitivity and especially the specificity of breast MRI in the non-screening setting as an adjunct to mammography sorted by breast density and to estimate the accuracy of breast MRI in cases rated BI-RADS 0 and 3 mammographically.
Material And Methods:
A total of 216 consecutive patients with referral to breast MRI and previously acquired mammography were enrolled in this analysis. Negative findings were followed up with a mean time of 26.7 months. The loss to follow-up was 10.8%. The single breast was regarded as the study subject (n=399, 364 cases were eligible for calculation of diagnostic accuracy). BI-RADS 1 and 2 were rated as benign, 4 and 5 as malignant. BI-RADS 0 and 3 were analyzed separately. The 95% confidence intervals (CIs) were calculated from the normally approximated binomial distribution and taken to represent significant differences for the two imaging modalities if they did not overlap.
Results:
Among the study population, 62 malignant neoplasms were detected. For cases rated BI-RADS 1, 2, 4, and 5 (n=251), the sensitivity of breast MRI was 95.7% (95% CI 89.9-100.0%) and 74.5% (95% CI 62.0-87.0%) for mammography, respectively. The specificity of breast MRI was 96.1% (95% CI 93.4-98.8%) and 92.2% (95% CI 88.5-95.9%) for mammography, respectively. The diagnostic accuracy of breast MRI did not depend on breast density. In cases rated BI-RADS 0, n=57 (3, n=56), breast MRI achieved a sensitivity of 100% (90.9%) and a specificity of 98.1% (88.9%). There was a significant (P< 0.01) accumulation of dense breast tissue (ACR IV) in breasts rated BI-RADS 0 in mammography. Breast MRI missed three malignant lesions, two of them being smaller than 3 mm.
Conclusion:
There is no rationale to criticize the low specificity of breast MRI when used as an adjunct to mammography. The independency of the diagnostic accuracy of breast MRI from breast density makes it a worthwhile choice in mammographic BI-RADS 0 cases.
More Related Videos
Related Concept Videos
Magnetic Resonance Imaging
Imaging Studies IV: Magnetic Resonance Imaging
Imaging Studies for Cardiovascular System IV: CMRI
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...